YOKOGAWA WT1804 CALIBRATION and YOKOGAWA WT1804 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT1804 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT1804   Description / Specification:    
YOKOGAWA WT1804 Four Input Element High Performance Power Analyzer

The Yokogawa WT1804 Four Input Element High Performance Power Analyzer has innovative functions that help improve measurement efficiency; Motor, Inverter, Lighting, EV/HEV, Battery, Power Supply, Aircraft, New Energy, Power Conditioner. Direct input of measurement signals makes it possible to measure very small current that can hardly be measured with a current sensor. The WT1804 provides a direct input voltage range from 1.5 V to 1000 V (12 ranges) and a direct input current range from 10 mA to 5 A (9 ranges) or from 1 A to 50 A (6 ranges). The frequency lower limit has been reduced to 0.1 Hz from the previous 0.5 Hz (5-fold lower than the previous model) to meet the requirement for power measurements at a low speed. Furthermore, high-speed data collection at a data update rate of up to 50 ms has been inherited. In addition to normal measurement data, up to the 500th order harmonic data can be measured and saved simultaneously. The data update rate can be selected from nine options from 50 ms to 20 s. Specifications. Basic power accuracy (50/60Hz): 0.1% of reading + 0.05% of range. Power frequency range: DC, 0.1 Hz ~ 1 MHz. Input elements: 4. Voltage range: 1.5/ 3/ 6/ 10/ 15/ 30/ 60/ 100/ 150/ 300/ 600/ 1000 [V]. Current range (direct input): 10m/ 20m/ 50m/ 100m/ 200m/ 500m/ 1/ 2/ 5 [A] or 1/ 2/ 5/ 10/ 20/ 50 [A]. Current range (external sensor input): 50m/ 100m/ 250m/ 500/ 1/ 2.5/ 5/ 10 [V]. Guaranteed accuracy range for voltage and current: 1% to 110%. Basic voltage/current accuracy: +/-0.1%. Basic power accuracy: +/-0.05%. Frequency range: DC, 0.1Hz to 1 MHz. Voltage/Current frequency range (-3 dB, typical): 5 MHz. Sampling speed: approximately 2 MS/s. Data update rate: 50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10, 20 [sec]. Line filter: OFF, digital filter 100 Hz to 100 kHz (100 Hz step) analog filter 300 kHz, 1 MHz. Frequency filter: OFF, 100 Hz or 1 kHz. Fundamental frequency of the PLL source: 0.5 Hz to 2600 Hz (internal sampling clock), without external sampling clock function. Display: 8.4-inch color TFT LCD display, Total number of pixels* 1024 (horizontal) × 768 (vertical) dots. Options. /EX4, External current sensor input. /B5, Built-in printer. /G5, Harmonic Measurement. /G6, Simltaneous Dual Harmonic Measurement. /DT, Delta Computation. /FQ, Add-on Frequency Measurement. /V1, RGB output. /DA, 20-channel DA Outputs. /MTR, Motor Evaluation Function. /AUX, Auxiliary Sensor Inputs. /HS, High speed data capturing.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT1804. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your YOKOGAWA WT1804 CALIBRATION and/or YOKOGAWA WT1804 Four Input Element High Performance Power Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: