Keysight (Agilent) 3403C REPAIR and Keysight (Agilent) 3403C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3403C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3403C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) 3403C   Description / Specification:    
Keysight (Agilent) 3403C True RMS voltmeter

The HP 3403C True RMS voltmeter is usable from dc to 100 MHz. True rms is especially valuable for measurements of noise, multiplexed signals, modulated waves and signals with high harmonic content. The dB display option provides readings directly in dB, a major convenience to ac users. The dB reference to which the measurement is made is conveniently adjustable from the front panel to provide referenced dB measurements, or to provide a convenient means to offset the reading by as much as 13 dB for unreferenced measurements. Specifications. Ranges; Full range display: 10.00 mV (ac only); 100.0 mV; 1.000 V; 10.00 V; 100.0 V; 1000 V. Overrange: >90% on all ranges except as limited by max input voltage. AC frequency range Slow response: 2 Hz to 100 MHz. AC frequency range Fast response: 25 Hz to 100 MHz. Input characteristics; Input impedance: < 10 MHz): 1 V to 1000 V range: 10 Mohm ± 10% shunted by 24 pF ± 10%. 10 mV and 100 mV range: 20 Mohm ± 10% shunted by 20 pF ± 10%. Maximum input voltage High to low: 1000 V rms, 1500 peak on any range. Maximum dc voltage in ac mode: 500 V dc. Options. Opt 001, autoranging. Opt 003, remote control + digital output + autoranging. Opt 006, dB display.



 

Standard Calibration $530.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3403C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 3403C REPAIR and/or Keysight (Agilent) 3403C True RMS voltmeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: