ANRITSU MA24126A CALIBRATION and ANRITSU MA24126A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MA24126A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   ANRITSU MA24126A   Description / Specification:   Spec Sheet 
ANRITSU MA24126A 26 GHz, True-RMS, USB Power Sensor

The Anritsu MA24126A 26 GHz USB Power Sensor is designed to provide accurate average power measurements from 10 MHz to 26 GHz over 60 dB of dynamic range. It employs a "dual path" architecture that provides (similar to thermal sensor) True-RMS measurements over the entire frequency and dynamic range, enabling users to make highly accurate average power measurements for CW, multi-tone, and digitally modulated signal up to 26 GHz. The sensor has internal and external triggering capability that facilitates individual slot power measurements of TDMA waveforms as well as burst power measurements of periodic and non-periodic waveforms.

Specifications.
Frequency Range: 10 MHz to 26 GHz.
Dynamic Range: -40 dBm to +20 dBm.
SWR:
  <1.90, (10 MHz to 50 MHz)  
  <1.17 (50 MHz to 150 MHz),
  <1.12 (150 MHz to 2 GHz),
  <1.22 (2 GHz to 12 GHz),
  <1.25, (12 GHz to 18 GHz),
  <1.35, (18 GHz to 26 GHz).
Signal channel rise time: 8 µs typical.
Video bandwidth: 50 kHz typical.
Sampling rate: 140 ks/s, typical.
Measurement ranges:
  Range 1, +20 dBm to -7 dBm typical;
  Range 2, -7 dBm to -40 dBm typical;
  Auto ranging between range 1 and 2.
Linearity: <3%.
Noise:
  < 8 µW, Range 1;
  < 40 nW, Range 2.
RF Connector: K (m).



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MA24126A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your ANRITSU MA24126A CALIBRATION and/or ANRITSU MA24126A 26 GHz, True-RMS, USB Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: