Keysight (Agilent) 34401A REPAIR and Keysight (Agilent) 34401A CALIBRATION

The Keysight (Agilent) 34401A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 34401A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 34401A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) 34401A   Description / Specification:    
Keysight (Agilent) 34401A 6 1/2 Digit Digital Multimeter

The Agilent 34401A 6 1/2-Digit, 12 measurement function Multimeter's clear, logical front panel allows you to easily select all primary measurement functions. Traditional "bench" functions, such as continuity and diode test, are included. Math functions, such as NULL, dB, dBm, limit test, and min/max/avg are easily selected. A simple menu scheme gives you access to powerful advanced features, such as the ability to store up to 512 readings in internal memory. Measurement results are displayed on a bright, high-visibility readout. A rugged case ensures survival even under the toughest conditions. Performance Features are. DC Volts -- 5 ranges: 0.1 V to 1000 V; Basic 1 yr. accuracy: 35 ppm; Maximum sensitivity: 100 nV; Maximum reading rate: 1,000 rdg/s. Resistance -- 7 ranges: 100 ohm to 100 M-ohm; Basic 1 yr. accuracy: 0.01%; Maximum sensitivity: 10 µ ohm; 2-wire and 4-wire ohm. AC Volts -- 5 ranges: 100 mV to 750 V; Basic 1 yr. accuracy: 0.06%; Bandwidth: 3 Hz to 300 kHz; Maximum Reading Rate: 10 readings/s (50 readings/s with default delays defeated); Maximum Volt–Hz Product: 8 x 10 ^7. DC Current -- 4 ranges: 10 mA to 3 A. AC Current -- 2 ranges: 1 A to 3 A; 3 Hz to 5 kHz bandwidth. Frequency and Period -- Range: 3 Hz to 300 kHz (333 ms to 3.33 µs); 1-Year Accuracy: 0.01% (40 Hz to 300 kHz); 0.05% (3 to 40 Hz); Resolution: 10 µHz to 1 Hz



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 34401A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 34401A REPAIR and/or Keysight (Agilent) 34401A 6 1/2 Digit Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: