Keysight (Agilent) 34405A CALIBRATION and Keysight (Agilent) 34405A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 34405A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) 34405A   Description / Specification:    
Keysight (Agilent) 34405A 5 1/2 Digit Digital Multimeter

The Agilent 34405A 5.5 Digit Dual Display, Benchtop DMM provides a broad range of features and measurement functions such as DC voltage, DC current, true-RMS AC voltage and AC current, 2-wire resistance, frequency, diode test and continuity which are designed to meet general industrial needs. Furthermore, it can measure temperature ranging from -80C to 150C. The true value is more evident with its capability to measure capacitance ranging from 1000 pF to 10000 mF. The Agilent 34405A also improves efficiency and accuracy with its 6 built-in math operations: Null, dBm, dB, MinMax, Limit and Hold. It can take up to 19 readings/sec at 4.5 digits resolution directly to the PC. Performance Features are. DC Voltage, 5 ranges: 100.000 mV to 1000.00 V. Resistance, 7 ranges: 100.000 ohm to 100.000 M-ohm. DC Current, 4 ranges: 10.0000 mA to 10.0000 A. Continuity: 1000 ohm, 0.83 mA. Diode Test: 1.0000 V, 0.83 mA. True-RMS AC Volts, ranges: 100.000 mV, 1.00000 V to 750.00 V. True-RMS AC Current, ranges: 100.000 mA to 10.0000 A. Frequency Range: 300 kHz. Temperature: -80 °C to 150 °C, - 110.0 °F to 300.0 °F. Capacitance, 6 ranges: 1.000 nF to 10.000 µF.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 34405A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 34405A CALIBRATION and/or Keysight (Agilent) 34405A 5 1/2 Digit Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: