Keysight (Agilent) N3970A CALIBRATION and Keysight (Agilent) N3970A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N3970A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Meter?
Shop for Comparable Products on our
 used Optical Power Meter page or new Optical Power Meter page

 
   Keysight (Agilent) N3970A   Description / Specification:   Spec Sheet 
Keysight (Agilent) N3970A 850 to 1650 nm Handheld Optical Power Meter

The Agilent N3970A Handheld Optical Power Meter is a high-end, user-friendly, wide dynamic range device featuring three percent overall accuracy, quick response time and no need for a warm-up period. Specifications. Sensor: Element InGaAs. Wavelength Range: 850 to 1650 nm. Calibration Wavelengths: 850, 1300, 1310, 1550 nm. Power Range: +5 to –60 dBm (850 nm), +5 to –70 dBm (other wavelengths). Maximum Input Power: +15 dBm. Uncertainty at reference conditions: ±0.13 dB (±3%). Total Uncertainty: ±0.3 dB (±7%) ±2 pW. Autotest sensitivity (typical): -40 dBm (850 nm), -50 dBm (other wavelengths). Operating Time: 250 hours. Applicable Fiber Type: 9/125 µm to 62.5/125 µm. Optical Input: Non-Contact, Removable Connector Adaptors. Display Type: LCD, 4 digits. Display Resolution: 0.01dB, 3 digits in linear mode. Display Units: dB, dBm, nW, µW, mW.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N3970A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your Keysight (Agilent) N3970A CALIBRATION and/or Keysight (Agilent) N3970A 850 to 1650 nm Handheld Optical Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: