A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS 380926 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   EXTECH INSTRUMENTS 380926   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS 380926 2000 Amp True RMS AC/DC Clamp Meter/DMM

The Extech 380926 2000 Amp True RMS AC/DC Clamp Meter features a rugged 2" (50mm) jaw to accomodate one 2000 MCM or two 500 MCM cables. Large 4000 count backlit display for high resolution and easy viewing in dimly lit areas. Full function autoranging DMM includes AC/DC Voltage and Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode and Continuity. DCA push button zero, Relative measurements and Data Hold. Specifications. DC/AC Current (Clamp): 400A, 2000A (0.1A Maximum Resolution). DC/AC Current (Clamp) Basic accuracy: ±(2% + 5d). DC/AC Current (DMM): 400 µA, 4000 µA, 40 mA, 400 mA (0.1 µA Maximum Resolution). DC/AC Current (DMM) Basic accuracy: ±(1.22% + 5d). DC Voltage: 400mV, 4V, 40V, 400V, 1000V (0.1 mV Maximum Resolution). DC Voltage Basic accuracy: ±(1% + 2d). AC Voltage: 4V, 40V, 400V, 1000V (1 mV Maximum Resolution). AC Voltage Basic accuracy: ±(1.2% + 5d). Resistance: 400, 4k, 40k, 400k, 4M, 40Mohm (0.1 ohm Maximum Resolution). Resistance Basic accuracy: ±(1% + 5d). Capacitance: 50 nF, 500 nF, 5 µF, 50 µF (10 pF Maximum Resolution). Capacitance Basic accuracy: ±(3% + 5d). Frequency: 5 Hz, 50 Hz, 500 Hz, 5 kHz, 50 kHz, 100 kHz (0.01Hz Maximum Resolution). Frequency Basic accuracy: ±(1% + 5d). Duty Cycle: 1 to 99.0% (0.1% Maximum Resolution). Duty Cycle Basic accuracy: ±(1% + 5d). Diode Check: yes. Continuity: yes.



 

Standard Calibration $205.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS 380926. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your EXTECH INSTRUMENTS 380926 CALIBRATION and/or EXTECH INSTRUMENTS 380926 2000 Amp True RMS AC/DC Clamp Meter/DMM REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: