Keysight (Agilent) 3458A REPAIR and Keysight (Agilent) 3458A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3458A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3458A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) 3458A   Description / Specification:    
Keysight (Agilent) 3458A 8 1/2 Digit Digital Multimeter

The HP 3458A 8 1/2 Digit Multimeter has high-test system throughput with Up to 100,000 reading/s, Internal test setups > 340/s and Programmable integration times from 500 ns to 1 s. Performance Features. DC Volts: 5 ranges, 0.1 V to 1000 V. 8 1/2 to 4 1/2 digits resolution. Up to 100,000 readings/s (4 1/2 digits). Maximum sensitivity: 10 nV. 0.6 ppm 24-hr accuracy. 8 ppm (4 ppm opt)/yr voltage reference stability. Resistance: 9 ranges, 10 ohm to 1 G ohm. 2-wire and 4-wire ohm with offset compensation. Up to 50,000 readings/s (5 1/2 digits). Maximum sensitivity: 10 µ ohm. 2.2 ppm 24-hour accuracy. AC Volts: 6 ranges, 10 mV to 1000 V. 1 Hz to 10 MHz bandwidth. Up to 50 readings/s with all readings to specified accuracy. Choice of sampling or analog true rms techniques. 100 ppm best accuracy. DC Current: 8 ranges, 100 nA to 1 A. Up to 1,350 readings/s (5 1/2 digits). Maximum sensitivity, 1 pA. 14 ppm 24-hr accuracy. AC Current: 5 ranges, 100 µA to 1 A. 10 Hz to 100 kHz bandwidth. Up to 50 readings/second. 500 ppm 24-hr accuracy. Frequency and Period: Voltage or current ranges. Frequency, 1 Hz to 10 MHz. Period, 100 ns to 1 second. 0.01% accuracy. AC or dc coupled.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3458A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 3458A REPAIR and/or Keysight (Agilent) 3458A 8 1/2 Digit Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: