Keysight (Agilent) 346B CALIBRATION and Keysight (Agilent) 346B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 346B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 346B   Description / Specification:    
Keysight (Agilent) 346B 18 GHz Broadband Noise Source

The Agilent 346B broadband noise source eliminates the necessity for several sources at different frequency bands. The 346B noise source has individually calibrated ENR values at specific frequencies. The 346B’s high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Specifications. Frequency Range: 10 MHz to 18 GHz. Excess Noise Ratio (ENR) Limits: 14 to 16 dB. Maximum SWR (reflection coefficient) on and off: (10 to 30 MHz - 1.3 (0.13); 30 to 5000 MHz - 1.15 (0.07); 5 to 18 GHz- 1.25 (0.11). Options. Opt 001 Type-N (male) Connector. Opt 002 7mm Connector. Opt 004 Type-N (female) Connector. Opt H01 High ENR. Opt H42 DBS Noise Source.



 

Standard Calibration $805.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 346B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 346B CALIBRATION and/or Keysight (Agilent) 346B 18 GHz Broadband Noise Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: