A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 346B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 346B   Description / Specification:    
Keysight (Agilent) 346B 18 GHz Broadband Noise Source

The Agilent 346B broadband noise source eliminates the necessity for several sources at different frequency bands. The 346B noise source has individually calibrated ENR values at specific frequencies. The 346B’s high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Specifications. Frequency Range: 10 MHz to 18 GHz. Excess Noise Ratio (ENR) Limits: 14 to 16 dB. Maximum SWR (reflection coefficient) on and off: (10 to 30 MHz - 1.3 (0.13); 30 to 5000 MHz - 1.15 (0.07); 5 to 18 GHz- 1.25 (0.11). Options. Opt 001 Type-N (male) Connector. Opt 002 7mm Connector. Opt 004 Type-N (female) Connector. Opt H01 High ENR. Opt H42 DBS Noise Source.



 

Standard Calibration $805.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 346B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 346B CALIBRATION and/or Keysight (Agilent) 346B 18 GHz Broadband Noise Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: