TEKTRONIX DSA70604C CALIBRATION and TEKTRONIX DSA70604C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DSA70604C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DSA70604C   Description / Specification:   Spec Sheet 
TEKTRONIX DSA70604C 4 Ch 6 GHz Digital Serial Analyzer

The Tektronix DSA70604C with 4 analog channels has a high signal-to-noise ratio and low internal noise floor. It allows you to find the smallest anomalies affecting the DUT's performance. Bandwidth enhancement eliminates imperfections in frequency response all the way to the probe tip. User-selectable filters for each channel provide magnitude and phase correction for more accurate representation of extremely fast signals. 
Specifications.

Analog channels: 4.
Analog bandwidth (user-selectable DSP enhance) (-3 dB): 6 GHz.
Hardware Analog Bandwidth (-3 dB): 4 GHz).
Rise time (typical): 65 ps (10% to 90%), 45 ps (20% to 80%).
Sample rate (1, 2 ch): 25 GS/s (maximum sample rate is 50 GS/s on digital channels routed to an analog channel through the iCapture™ analog mux).
Sample rate (3, 4 ch): 25 GS/s.
Record length, points (each channel, standard): 31.25 M. 
Timing resolution: 40 ps (25 GS/s).

Vertical system - Analog channels.
DC gain accuracy: ±2% (of reading).
Channel delay (typical): <=10 ps for any two channels at equal V/div and coupling.
Signal-to-Noise ratio (typical): 34 dB.
Input coupling: DC (50 Ω), GND.
Input resistance selection: 50 Ω ±3%, 1 MΩ with TCA-1MEG adapter.
Input sensitivity range: 10 mV/div to 500 mV/div (100 mV to 5 V full scale).
Maximum input voltage, 50 Ω: <5.0 VRMS for >=100 mV/div; 1.0 VRMS for <100 mV/div. 

Horizontal system.
Channel-to-Channel: deskew range ±75 ns.
Time base accuracy: ±1.5 ppm initial accuracy, aging <1 ppm per year.
Time base delay time range: -5.0 ks to 1.0 ks.
Trigger jitter: <100 fsRMS (1 psRMS [typical] with enhanced triggering off).



 

Standard Calibration $390.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DSA70604C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX DSA70604C CALIBRATION and/or TEKTRONIX DSA70604C 4 Ch 6 GHz Digital Serial Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: