Keysight (Agilent) E5505A CALIBRATION and Keysight (Agilent) E5505A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5505A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Noise Analyzer? Shop for Comparable Products on our   new RF Noise Analyzer page

 
   Keysight (Agilent) E5505A   Description / Specification:   Spec Sheet 
Keysight (Agilent) E5505A 26.5 GHz Phase Noise Measurement Solution

The Keysight Technologies E5505A 26.5 GHz phase noise measurement solution offers the most flexible set of measurements on one-port VCOs, DROs, crystal oscillators and synthesizers. Two-port devices, including amplifiers and converters, plus CW, pulsed and spurious signals can also be measured. The E5505A measurements include absolute and residual phase noises, AM noise, and low-level spurious signals. The stand-alone instrument architecture easily configures for various measurement techniques, including the PLL/reference source technique, residual and FM discriminator methods. It includes a baseband test set: N5500A-7011 Standard configuration, 50 kHz to 1.6 GHz, 0 to 23 dBm; N5500A-001 High power, 0 to 30 dBm, high frequency input, 1.2 to 26.5 GHz, and AM noise or N5500A-201 High frequency input, 1.2 to 26.5 GHz, 0 to 23 dBm. A low noise microwave downconverter: E5505A-100 Downconverter not included; N5502A Low noise 18 GHz microwave downconverter or N5507A Low noise 26.5 GHz microwave downconverter. A baseband swept analyzer: E5505A-110 Spectrum analyzer not included; N9030A PXA high-performance signal analyzer (3 Hz to 3.6/8.4/13.6/26.5/43/44/50 GHz); N9020A MXA mid-performance signal analyzer (10 Hz to 3.6/8.4/13.6/26.5 GHz); N9010A EXA economy signal analyzer (10 Hz to 3.6/7.0/13.6/26.5/32/44 GHz); N9000A CXA low-cost signal analyzer (9 kHz to 3/7.5 GHz); E4411B ESA-L (9 kHz to 1.5 GHz) spectrum analyzer; E4402B ESA-E (100 Hz to 3 GHz) spectrum analyzer or E444xA PSA Series (3 Hz to 6.7/13.2/26.5/42.98/44/50 GHz) spectrum analyzer. Operating characteristics. Offset frequency range: 0.01 Hz to 2 MHz. System noise response: –180 dBc/Hz typically (>10 kHz offsets). System spurious response: < –120 dBc typically. Phase detector input power: (<1.6 GHz carrier frequency), R input = 0 to +23 dBm, L input = +15 to +23 dBm. Downconverter input range: 1 GHz to 18 GHz, 1.5 GHz to 26.5 GHz. External noise input port: 0.01 Hz to 100 MHz. Measurement accuracy: ±2 dB (< 1.0 MHz offsets), ±4 dB (< 100 MHz offsets).



 

Standard Calibration $1,100.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5505A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) E5505A CALIBRATION and/or Keysight (Agilent) E5505A 26.5 GHz Phase Noise Measurement Solution REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: