A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO91204A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO91204A   Description / Specification:    
Keysight (Agilent) DSO91204A 4 Ch 12 GHz Infiniium Oscilloscope

The Agilent DSO91204A 4 Ch 12 GHz Infiniium Oscilloscope boasts an ever-expanding set of measurement applications for serial debugging and protocol viewing, jitter testing, advanced triggering, measurement customization, and rapid automation. With 1 Gbyte of memory, low-frequency jitter components can be more quickly resolved in a single measurement. Statistical accuracy is improved with more data collection. Agilent's integrated deep memory remains responsive and allows more comprehensive testing, supporting pattern lengths up to PRBS23 for accurate transmitter and receiver results. Infiniium's built-in FFT allows users to quickly and easily analyze the frequency components of their signals. A resolution bandwidth of 6 kHz is supported with the standard 10 Megabytes of acquisition memory at the maximum sample rate of 40 GSa/s. Display: 12.1-inch color XGA TFT-LCD with touch screen.

Performance characteristics.

Vertical.
Input channels: Four.
Analog bandwidth (-3 dB): 12 Ghz.
Rise time/fall time: 35 ps (10 - 90%), 25 ps (20 - 80%).
Input impedance: 50 ohm, ± 3%.
Sensitivity: 1 mV/div to 1 V/div.
Input coupling: DC.
Vertical resolution: 8 bits, ≥ 12 bits with averaging.
DC gain accuracy: ± 2% of full scale at full resolution channel scale (± 2.5% for 5mV/div).
Maximum input voltage: ± 5 V.
Dynamic range: ± 4 div from center screen.
RMS noise floor (scope only): 435 µV (Volts/div, 5 mV), 28.5 µV (Volts/div, 1 V).

Horizontal.
Main timebase range: 5 ps/div to 20 s/div real-time, 5 ps/div to 500 ns/div equivalent-time.
Main timebase delay range: -200 s to 200 s real-time, -25 µs to 200 s equivalent-time.
Zoom timebase range: 1 ps/div to current main time scale setting.
Channel deskew: ± 25 µs range, 100 fs resolution.
Time scale accuracy: ± (0.4 + 0.5 * Yrs Since Cal) ppm pk.

Acquisition.
Maximum real-time sample rate: 40 GSa/s (4 channels simultaneously).
Memory depth per channel Standard: 20 Mpts on 4 channels.



 

Standard Calibration $565.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO91204A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) DSO91204A CALIBRATION and/or Keysight (Agilent) DSO91204A 4 Ch 12 GHz Infiniium Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: