THORLABS MCLS1 CALIBRATION and THORLABS MCLS1 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the THORLABS MCLS1 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Source (DFB-LD-WDM-BBS)?
Shop for Comparable Products on our
 used Laser Source (DFB-LD-WDM-BBS) page or new Laser Source (DFB-LD-WDM-BBS) page

 
   THORLABS MCLS1   Description / Specification:    
THORLABS MCLS1 4-Channel, Fiber-Coupled, Customizable Laser Source Series

The Thorlabs MCLS1 4-Channel, Fiber-Coupled, Customizable Laser Source series provides easy coupling and simple control of laser-diode-driven fiber optics. The laser source is configured to accept a wide range of fiber-pigtailed laser diodes with discrete wavelengths in the spectral range from 405 - 1550 nm, in any combination. The laser source allows more than one channel to be turned on simultaneously; however, it is only possible to adjust the power output of one at a time from the front panel.

Each laser diode is operated from an independent, high-precision, low-noise, constant-current source and temperature control unit. An intuitive LCD interface allows the user to view and set the laser current and temperature independently for each laser. The display indicates the channel number selected, the output wavelength of the source, the operating power calculated from the laser diode monitor diode, and the actual temperature the laser is set to.

Below is a list of available lasers listed by wavelength.

Item # --- Typical λ --- Wavelength Range --- Minimum Power --- Typical Power
MCLS1-405-30 --- (405 nm) --- (400 - 410 nm) --- (24.0 mW) --- (28 mW)
MCLS1-406 --- (406 nm) --- (395 - 415 nm) --- (4.0 mW) --- (6 mW)
MCLS1-473-20 --- (473 nm) --- (468 - 478 nm) --- (15.0 mW) --- (20 mW)
MCLS1-488 --- (488 nm) --- (483 - 493 nm) --- (18.0 mW) --- (22 mW)
MCLS1-520 --- (520 nm) --- (515 - 530 nm) --- (8.0 mW) --- (10.0 mW)
MCLS1-635 --- (635 nm) --- (630 - 640 nm) --- (2.5 mW) --- (3.5 mW)
MCLS1-638 --- (638 nm) --- (628 - 648 nm) --- (10.0 mW) --- (15 mW)
MCLS1-642 --- (642 nm) --- (635 - 645 nm) --- (15.0 mW) --- (20 mW)
MCLS1-658 --- (658 nm) --- (648 - 668 nm) --- (9.5 mW) --- (14 mW)
MCLS1-660 --- (660 nm) --- (653 - 663 nm) --- (15.0 mW) --- (17 mW)
MCLS1-670 --- (670 nm) --- (660 - 680 nm) --- (1.5 mW) --- (2.5 mW)
MCLS1-670-4 --- (670 nm) --- (660 - 680 nm) --- (4.0 mW) --- (5 mW)
MCLS1-685 --- (685 nm) --- (675 - 695 nm) --- (10.0 mW) --- (13.5 mW)
MCLS1-705 --- (705 nm) --- (695 - 715 nm) --- (10.0 mW) --- (15 mW)
MCLS1-730 --- (730 nm) --- (720 - 740 nm) --- (12.5 mW) --- (15.0 mW)
MCLS1-785 --- (785 nm) --- (770 - 800 nm) --- (6.0 mW) --- (7.5 mW)
MCLS1-785-25 --- (785 nm) --- (780 - 790 nm) --- (20.0 mW) --- (25 mW)
MCLS1-808-20 --- (808 nm) --- (803 - 813 nm) --- (20.0 mW) --- (25 mW)
MCLS1-830 --- (830 nm) --- (820 - 840 nm) --- (8.0 mW) --- (10 mW)
MCLS1-850 --- (850 nm) --- (840 - 860 nm) --- (7.5 mW) --- (10.5 mW)
MCLS1-850-MM --- (850 nm) --- (847 - 857 nm) --- (45.0 mW) --- (50 mW)
MCLS1-852 --- (852 nm) --- (847 - 857 nm) --- (20.0 mW) --- (25 mW)
MCLS1-905-20 --- (905 nm) --- (900 - 910 nm) --- (15.0 mW) --- (20 mW)
MCLS1-940 --- (940 nm) --- (930 - 950 nm) --- (25.0 mW) --- (30 mW)
MCLS1-980 --- (980 nm) --- (965 - 995 nm) --- (6.0 mW) --- (9 mW)
MCLS1-1064 --- (1064 nm) --- (1059 - 1069 nm) --- (20.0 mW) --- (25 mW)
MCLS1-1310 --- (1310 nm) --- (1290 - 1330 nm) --- (2.5 mW) --- (3 mW)
MCLS1-1310-15 --- (1310 nm) --- (1290 - 1330 nm) --- (13.0 mW) --- (15.0 mW)
MCLS1-1310DFB --- (1310 nm) --- (1290 - 1330 nm) --- (1.5 mW) --- (2 mW)
MCLS1-1550 --- (1550 nm) --- (1520 - 1580 nm) --- (1.5 mW) --- (2 mW)
MCLS1-1550-10 --- (1550 nm) --- (1530 - 1570 nm) --- (8.0 mW) --- (10.0 mW)
MCLS1-1550DFB --- (1550 nm) --- (1540 - 1560 nm) --- (1.5 mW) --- (2 mW)



 

Standard Calibration $595.00 *
*This is a Web introductory price for one calibration of the THORLABS MCLS1. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a fiber optic component, link or network will operate.

Extinction Ratio (ER)
Extinction Ratio is the ratio of two optical power levels, of a digital signal generated by an optical source, (example a laser diode), where P1 is the optical power level generated when the light source is "on," and P0 is the power level generated when the light source is "off." The extinction ratio may be expressed as a fraction, in dB, or as a percentage.

Optical Signal-to-noise Ratio (OSNR)
Optical Signal-to-noise ratio is the ratio between the signal power and the noise power in a given bandwidth. Most commonly a reference bandwidth of 0.1 nm is used. This bandwidth is independent from the modulation format, the frequency and the receiver. For instance a OSNR of 20dB/0.1nm could be given, even the signal of 40 GBit DPSK would not fit in this bandwidth. OSNR is measured with a Optical Spectrum Analyzer. It is generally measured at the wavelength of interest.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.

Wavelength Repeatability
Wavelength Repeatability is the random uncertainty in reproducing a wavelength after detuning and re-setting the wavelength. The wavelength repeatability is ± half the span between the maximum and the minimum value of all actual values of these wavelengths. Example test condition: uninterrupted TLS output power, constant power level, temperature within operating temperature range, coherence control off, short time span. Note: NOTE The long-term wavelength repeatability can be obtained by taken the wavelength repeatability and wavelength stability into account.


Please contact us for your THORLABS MCLS1 CALIBRATION and/or THORLABS MCLS1 4-Channel, Fiber-Coupled, Customizable Laser Source Series REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: