Keysight (Agilent) DSO1024A REPAIR and Keysight (Agilent) DSO1024A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) DSO1024A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO1024A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO1024A   Description / Specification:    
Keysight (Agilent) DSO1024A 4 Ch 200 MHz Oscilloscope

The Keysight DSO1024A 200 MHz oscilloscope comes equipped with 23 automatic voltage, time and frequency measurements. Record up to 1000 occurrences of a trigger event and then play them back to easily spot glitches or other anomalies for further examination. Apply a real-time digital filter of your choice to the input source waveform to eliminate unwanted frequencies from your display. Digital filtering selections include Low-pass, high-pass, band-pass and band-reject filters.
Specifications.

Bandwidth (-3 dB) : DC to 200 MHz.
Real time sample rate: 2 GSa/sec half channel interleaved, 1 GSa/sec all channels.
Channels: 4.
Memory: 20 kpts half channel interleaved, 10 kpts all channels.
Vertical resolution: 8 bits.
Vertical sensitivity: 2 mV/div to 10 V/div.
DC gain accuracy: 2 mV/div to 5 mV/div: ± 4.0% full scale; 10 mV/div to 5 V/div: ± 3.0% full scale.
Vertical zoom: Vertical expand.
Maximum input voltage: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk.
Time base range: 1 nsec/div to 50 sec/div.
Selectable BW limit: 20 MHz.
Horizontal modes: Main (Y-T), XY, delayed zoom and roll.
Input coupling: DC, AC, Ground.
Input impedance: 1 MΩ ± 1% in parallel with 18 pF ± 3 pF.
Time scale accuracy: ± 50 ppm from 0 °C to 30 °C, ± 50 ppm + 2 ppm per °C from 30 °C to 45 °C + 5 ppm × (years since manufacture).
Display: 5.7 inch diagonal color QVGA TFT LCD display with 300 cd/m2 backlight intensity.



 

Standard Calibration $300.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO1024A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) DSO1024A REPAIR and/or Keysight (Agilent) DSO1024A 4 Ch 200 MHz Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: