A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8267D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E8267D   Description / Specification:    
Keysight (Agilent) E8267D 250 kHz to 13/20/31.8/44 GHz PSG Vector CW Signal Generator

The Agilent E8267D PSG Vector Signal Generator delivers industry-leading output power, superior level accuracy, low phase noise, and precision modulation for accurate characterization of RF and microwave components and devices. It features: CW output from 250 kHz to the highest operating frequency, depending on the option. Frequency resolution to 0.001 Hz. List and step sweep of frequency and amplitude, with multiple trigger sources. User flatness correction. External diode detector leveling. Automatic leveling control (ALC) on and off modes; power calibration in ALC- off mode is available, even without power search. 10 MHz reference oscillator with external output. RS- 232, GPIB, and 10Base-T LAN I/O interfaces.
Specifications.

Frequency range: 250 kHz to 13/20/31.8/44 GHz (option dependent).
Frequency resolution, CW: 0.001 Hz.
High output power: +20 dBm (option dependent).
Spectral purity: -55 dBc (max).

Options.
513, Frequency range from 250 kHz to 13 GHz.
520, Frequency range from 250 kHz to 20 GHz.
532, Frequency range from 250 kHz to 31.8 GHz.
544, Frequency range from 250 kHz to 44 GHz.
602, Internal baseband generator, 64 MSa memory.
003, Digital output connectivity with N5102A.
004, Digital input connectivity with N5102A.
007, Analog ramp sweep.
009, 8 GB removable flash memory.
016, Wideband external I/Q inputs.
403, Calibrated AWGN.
409, Global positioning system (GPS) personality.
423, Scenario generator for GPS personality.
UNX, Ultra low phase noise.
UNY, Enhanced ultra low phase noise.
UNT, AM, FM, phase modulation, and LF output.
UNU, Pulse modulation.
UNW, Narrow pulse modulation.
1ED, Type-N (f) RF output connector.
1EH, Improved harmonics below 2 GHz.
1EM, Moves all front panel connectors to the rear panel.



 

Standard Calibration $1,025.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8267D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) E8267D CALIBRATION and/or Keysight (Agilent) E8267D 250 kHz to 13/20/31.8/44 GHz PSG Vector CW Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: