WITHWAVE WWNT CALIBRATION and WITHWAVE WWNT REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the WITHWAVE WWNT Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration / Verification Kits? Shop for Comparable Products on our   new Calibration / Verification Kits page

 
   WITHWAVE WWNT   Description / Specification:   Spec Sheet 
WITHWAVE WWNT Type-N 6 GHz Compact Calibration Kit

The Withwave WWNT Compact N-Type Calibration Kits offers excellent performance characteristics that is specially designed for the fine-tuning in production environments and quality testing facilities using 50 ohm N-type connectors from DC to 6 GHz.
This Cal. Kit include all needed calibration standard (Open, Short, Load) in one unit. It is best solution for available for ease of use in VNA calibration, especially in the field.
Specifications. 

Electrical.
Frequency Range: DC to 6 GHz.
Impedance: 50 Ohm.
Return loss LOAD: < 38 dB.
Phase deviation (OPEN, SHORT): < 1.5 degrees. 

Mechanical.
Connector type: N-Type (Male).
Housing: Stainless steel.
Weight: 177 g.



 

Standard Calibration $415.00 *
*This is a Web introductory price for one calibration of the WITHWAVE WWNT. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your WITHWAVE WWNT CALIBRATION and/or WITHWAVE WWNT Type-N 6 GHz Compact Calibration Kit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: