BERKELEY NUCLEONICS CORPORATION 645 CALIBRATION and BERKELEY NUCLEONICS CORPORATION 645 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BERKELEY NUCLEONICS CORPORATION 645 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
For Sale New, List Price $1,425.00   BERKELEY NUCLEONICS CORPORATION 645   Description / Specification:   Spec Sheet 
BERKELEY NUCLEONICS CORPORATION 645 50 MHz Function/Arbitrary Waveform Generator

The BNC 645 50MHz Function/Arbitrary Waveform Generator delivers many advanced features and user modes. New DDS+ technology embraces advancements in the semiconductor industry and leverages state-of- the-art components for both standard and complex functions.
The Model 645 can generate variable-edge pulses at rates up to 10MHz. From the front panel or through remote communications, the user may vary the period, pulse width and amplitude. The pulse parameters may be stored in the unit or on your computer for later recall.
The BNC 645 offers 14-bit resolution and a 125 MSa/s sampling rate, giving users enough control of their waveforms for most applications. It will storage of up to 5 waveforms concurrently ( 4 waveforms (4 x 256K points) in nonvolatile memory and 1 waveform in volatile memory.
Specifications.

Capability.
Standard Wave forms: Sine, Square, Ramp, Triangle, Pulse, Noise, DC .
Built-in arbitrary waveforms: Exponential Rise and Fall, Negative ramp, Sin (x)/x, Cardiac.
Modulation Types: AM, FM, PM, FSK, PWM, Sweep and Burst.

Waveform Characteristics.
Sine
Frequency: 1 µHz 50 MHz.
Amplitude: 0.1 dB (< 100 KHz).
Flatness: 0.15dB (<5MHz).
Total Harmonic Distortion: DC to 20 KHz, Output ≥ 0.5Vpp THD+N ≤0.06%.
Square
Frequency: 1 µHz to 25 MHz .
Rise/ Fall time: < 10 ns .
Overshoot: < 2%.
Variable Duty Cycle: 20% to 80% (to 10MHz), 40% to 60% (to 25 MHz).
Asymmetry: 1% of period + 5 ns (@ 50% duty).
Ramp, Triangle
Frequency: 1 µHz to 200 KHz.
Linearity: < 0.1% of peak output.
Symmetry: 0.0% ~ 100.0%.
Noise
Bandwitdh: 20 MHz Typical.
Arbitrary
Frequency: 1 µHz to 10MHz.
Length: 2 to 256 K.
Resolution: 14 bits (Including sign).
Sample Rate: 125 MSa/s.
Min Rise/ Fall: 30 ns typical.
Linearity: < 0.1% of peak output.
Settling Time: <250 ns to 0.5% of final value.

Common Characteristics.
Frequency Resolution: 1µHz.
Amplitude Range: 10mVpp to 10Vpp in 50Ω, 20mVpp to 20 20Vpp in Hi-Z.
Amplitude Accuracy (at 1KHz): ±1% of setting ±1mVpp.
DC Offset Range (Peak AC + DC): ±2% of offset setting, ±0.5% of amplitude setting.



 

Standard Calibration $405.00 *
*This is a Web introductory price for one calibration of the BERKELEY NUCLEONICS CORPORATION 645. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your BERKELEY NUCLEONICS CORPORATION 645 CALIBRATION and/or BERKELEY NUCLEONICS CORPORATION 645 50 MHz Function/Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*