FLUKE 7526A CALIBRATION and FLUKE 7526A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 7526A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration Standard? Shop for Comparable Products on our   new Calibration Standard page

 
   FLUKE 7526A   Description / Specification:    
FLUKE 7526A Precision Process Calibrator

The Fluke Calibration 7526A Precision Process Calibrator offers the best balance of economy and accuracy for benchtop calibration of pressure and temperature process instrumentation. Incorporating an isolated measurement channel, the 7526A lets you simultaneously source and measure voltage, current or resistance, making it easy to calibrate temperature and pressure transmitters, RTD and thermocouple readouts, pressure gauges, digital process simulators, data loggers, multimeters and more.
Specifications.

DC voltage, output.
Range / Absolute uncertainty, ± (output + V), 1 year / Resolution.
  0 mV to 100 mV / 30 ppm + 3 μV / 1 μV,
  0 V to 1 V / 30 ppm + 10 μV / 10 μV,
  0 V to 10 V / 30 ppm + 100 μV / 100 μV,
  0 V to 100 V / 30 ppm + 1 mV / 1 mV.

DC voltage, isolated input.
Range / Absolute uncertainty, ± (reading + V), 1 year / Resolution.
  0 V to 10 V / 100 ppm + 0.2 mV / 100 μV,
  10 V to 100 V / 100 ppm + 2.0 mV / 1 mV.

DC current, output.
Range / Absolute uncertainty, ± (reading + A), 1 year / Resolution.
  0 mA to 100 mA / 50 ppm + 1 μA / 1 μA.

DC current, isolated input.
Range / Absolute uncertainty, ± (reading + A), 1 year / Resolution.
  0 mA to 50 mA / 100 ppm + 1 μA / 1 μA,
  0 mA to 24 mA / 100 ppm + 1 μA / 1 μA.

Resistance, output.
Range / Absolute uncertainty, tcal ± 5 °C, ± ohms, 1 year / Resolution / Nominal current.
  5 Ω to 400 Ω / 0.015 / 0.001 Ω / 1 mA to 3 mA,
  5 Ω to 4 kΩ / 0.3 / 0.01 Ω / 100 μA to 1 mA.

Resistance, input.
Range / Absolute uncertainty, ± (reading + Ω), 1 year / Resolution.
  0 Ω to 400 Ω / 20 + 0.004 / 0.001 Ω,
  0 Ω to 4 kΩ / 20 + 0.04 / 0.01 Ω.

Sample thermocouple accuracy, input/output (does not include all available TC types).
TC type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  J / -210 to 1200 / 0.09.
  K / -250 to 1372 / 0.1,
  S / -50 to 1767 / 0.29,
  T / -250 to 400 / 0.11.

Sample RTD and thermistor, output (does not include all available RTD types).
RTD type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  Pt 385 100 Ω / -200 to 800 / 0.05,
  YSI 400 / 15 to 50 / 0.007.

Sample RTD and thermistor, output (does not include all available RTD types).
RTD type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  Pt 385 100 Ω / -80 to 100 / 0.020,
  Pt 385 100 Ω / 100 to 300 / 0.024,
  Pt 385 100 Ω / 300 to 800 / 0.026,
  YSI 400 / 15 to 50 / 0.007.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your FLUKE 7526A CALIBRATION and/or FLUKE 7526A Precision Process Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: