A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2925 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2925   Description / Specification:    
SLAUGHTER 2925 5KV AC Withstanding Voltage Tester

The Slaughter 2925 Hipot tester was designed to provide safe, reliable, and cost-effective electrical safety testing. It complies with agency requirements from such agencies as UL, TÜV, CSA, VDE, and IEC.
Specifications.

Dielectric Withstand Test Mode.
Input Voltage: 115/230V selectable, ± 15% variation 47 - 63Hz.
Output Rating: AC 0 - 5000V, 2V/step, 12mA.
Output Regulation: ± (1% of output + 5V).
Voltage Setting: 0V - Max output rating, 10 volt step.
Voltage Setting Accuracy: ± (2% of Setting + 5V) (relative to displayed output).
Output Frequency: 50/60Hz selectable.
Wave Form Sinewave Distortion : < 2% THD.
Dwell Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step “0” for continuous running.
Ramp Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step 0 ramp setting = 0.1 seconds fixed ramp.
Failure Settings AC Mode;
  High limit: 0.10 - 12.00mA, 0.01mA/step.
  Low limit: 0.00, 0.10 - 12.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Discharge Time: ≤ 300ms.
Ground Continuity Check;
  Current: DC 0.1A ± 0.01A, fixed.
  Maximum ground resistance: 1Ω ± 0.1Ω, fixed.



 

Standard Calibration $635.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2925. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your SLAUGHTER 2925 CALIBRATION and/or SLAUGHTER 2925 5KV AC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: