CUSTOM-CAL CC50-3.5-8 CALIBRATION and CUSTOM-CAL CC50-3.5-8 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the CUSTOM-CAL CC50-3.5-8 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration / Verification Kits? Shop for Comparable Products on our   new Calibration / Verification Kits page

 
For Sale New, List Price $2,950.00   CUSTOM-CAL CC50-3.5-8   Description / Specification:    
CUSTOM-CAL CC50-3.5-8 50 ohm 8.5 GHz 3.5 mm Calibration Kit

The Custom-Cal CC50-3.5-8 is a 50 Ohm, DC to 8.5 GHz, 3.5 mm-type Standard Calibration Kit. It consists of a; CC-5001-OF Open Female Connector, CC-5001-OM Open Male Connector, CC-5001-SF Short Female Connector, CC-5001-SM Short Male Connector, CC-5001-LF Load Female Connector, CC-5001-LM Load Male Connector, CC-5001-TF Through Female to Female Connector, CC-5001-TM Through Male to Male Connector, 7mm flat wrench and a 8710-1765CC 8 in-lbs [0.9 N.m] Break-Over Torque Wrench.
Specifications.
Open Female Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Phase (DC to 3000 MHz): 0.8 degree.
Phase (3001 to 8500 MHz): 1.2 degree.
Open Male Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Phase (DC to 3000 MHz): 0.8 degree.
Phase (3001 to 8500 MHz): 1.2 degree.
Short Female Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Phase (DC to 3000 MHz): 0.8 degree.
Phase (3001 to 8500 MHz): 1 degree.
Short Male Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Phase (DC to 3000 MHz): 0.8 degree.
Phase (3001 to 8500 MHz): 1 degree.
Load Female Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Return Loss (DC to 3000 MHz): 40 dB minimum.
Return Loss (3001 to 8500 MHz): 36 dB minimum.
Load Male Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Return Loss (DC to 3000 MHz): 40 dB minimum.
Return Loss (3001 to 8500 MHz): 36 dB minimum.
Through Female Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Insertion Loss (DC to 8500 MHz): 0.2 dB maximum.
Return Loss (DC to 8500 MHz): 30 dB minimum.
Through Male Connector.
Frequency Range: DC to 8500 MHz.
Impedance: 50 Ω.
Insertion Loss (DC to 8500 MHz): 0.2 dB maximum.
Return Loss (DC to 8500 MHz): 30 dB minimum.



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the CUSTOM-CAL CC50-3.5-8. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your CUSTOM-CAL CC50-3.5-8 CALIBRATION and/or CUSTOM-CAL CC50-3.5-8 50 ohm 8.5 GHz 3.5 mm Calibration Kit REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: