ANRITSU MP2101A CALIBRATION and ANRITSU MP2101A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MP2101A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Bit Error Rate Tester (BERT)?
Shop for Comparable Products on our
 used Bit Error Rate Tester (BERT) page or new Bit Error Rate Tester (BERT) page

 
   ANRITSU MP2101A   Description / Specification:    
ANRITSU MP2101A BERTWave PE, BERT

The Anritsu MP2101A BERTWave PE is a BER tester supporting 125 Mbit/s to 12.5 Gbit/s. The BERT function supports bit rate from 125 Mbit/s to 12.5 Gbit/s (with Option-090) for evaluating devices and application supporting STM-1, 10 GFC and etc…
Specifications.

PPG.
Internal Reference Clock Accuracy: ±10 ppm Offset Variability: ±100 ppm, 1 ppm step.
Data Output Amplitude: Variable 0.1 Vp-p to 0.8 Vp-p, 10 mV step, AC coupled.
Data Output Amplitude Accuracy: ±20 mV ±20% for settings.
Test Pattern PRBS: 27 - 1, 29 - 1, 215 - 1, 223 - 1, 231 - 1 (Invert ON/OFF).
Test Pattern User Data: 1.3 Mbits (Editable Text File, Presence Sample File).

ED.
Offset Capacity: ±100 ppm.
Electrical Data Input 0.1 Vp-p to 0.8 Vp-p, DC coupled: 8.5 Gbit/s to 11.32 Gbit/s and 1/N bit rate above (10.3125 Gbit/s, single-ended 0.1 Vp-p, loopback, PRBS31, mark ratio 1/2, 20° to 30°C, BER <1E-12)
Test Pattern PRBS: 27 - 1, 29 - 1, 215 - 1, 223 - 1, 231 - 1 (Invert ON/OFF).
Test Pattern User Data: 1.3 Mbits (Editable Text File, Presence Sample File).

BERT.
External 10 MHz Input Connector;
Amplitude: 0.7 Vp-p to 2 Vp-p, AC coupled.
Connector: BNC connector, 50 Ω.
Waveform: Square or Sine wave.

External Reference Clock Input;
External: 1/16 Clock Input.
Amplitude: 0.2 Vp-p to 1.5 Vp-p, AC coupled.
Connector: SMA connector, 50 Ω.
Waveform: Square or Sine wave.

Options.
-011, 1CH PPG/ED.
-012, 2CH PPG/ED.
-030, GPIB.
-050, XFP Slot.
-051, SFP+ Slot.
-052, Full Rate Clock Output.
-090, Bit Rate Extension for PPG/ED.
-091, ED High Sensitivity.



 

Standard Calibration $1,340.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MP2101A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

PDH
Plesiochronous Digital Hierarchy (PDH) is a transmission system for voice communication using plesiochronous synchronisation. The transmitter adds dummy information bits to allow multiple channels to be bit interleaved. The receiver discards these bits once the signals have been demultiplexed. PDH combines multiple 2 Mb/s (E1) channels in Europe and 1.544 Mb/s (DS1) channels in the US and Japan.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).


Please contact us for your ANRITSU MP2101A CALIBRATION and/or ANRITSU MP2101A BERTWave PE, BERT REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: