MEGGER MJ159 CALIBRATION and MEGGER MJ159 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MJ159 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MJ159 (212159)   Description / Specification:    
MEGGER MJ159 100/250/500/1000 V Insulation Tester

The Megger MJ159 insulation tester is designed to give rapid, accurate and direct measurement of continuity and insulation resistance of domestic and industrial wiring, cables, transformers, motors, generators electrical machinery and appliances.
It is self-powered, and is suitable for use during installation and commissioning work as well as for service and maintenance applications.
Specifications.

Insulation Range.
Insulation Resistance: 0.1Ω - 2000 MΩ.
Nominal Test Voltages dc: 100 V, 250 V, 500 V, 1000 V.
Accuracy: 250 V, 500 V, 1000 V +30%, -0% maximum; 100 V, +40%, -0% maximum.
Midscale: 4 MΩ.
Short Circuit Current: 1.9 mA.
Accuracy: ±1.25% of fsd on a 2.8 in. (71.1mm) arc length: [0.035 in. (0.9mm)].

Resistance Range.
Range: 0.1Ω - 5000Ω.
Open circuit Test voltage: 3 V ±0.2 V.
Short Circuit Current: 2 mA ±10%.
Accuracy: ±1.25% of fsd on a 2.8 in. (71.1mm) arc length: [0.035 in. (0.9mm)].
Maximum Load Capacitance: 1μF with less than ±0.1” pointer movement.
Discharge: Up to 1μF capacitance is discharged from 1000V to less than 42.4 V in less than 4 seconds.

Safety Voltage Check.
Voltage measurement: 0.1 V - 600 V ac; the meter is RMS calibrated and average responding.
Safety voltage indicator: Indicates the presence of dc voltages, scaling is not the same as the ac meter; true dc voltage equals scale reading divided by 2.22.
Accuracy: 2.5% of full scale.

Power Supply.
Low voltage brushless ac generator, cranking speed between 130 rpm and 170 rpm.



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MJ159. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your MEGGER MJ159 CALIBRATION and/or MEGGER MJ159 100/250/500/1000 V Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: