Keysight (Agilent) N9342C CALIBRATION and Keysight (Agilent) N9342C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N9342C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) N9342C   Description / Specification:    
Keysight (Agilent) N9342C 7 GHz Handheld Spectrum Analyzer

The Keysight N9342C 7 GHz handheld spectrum analyzer (HSA) puts the speed and performance of spectrum analysis in the hands of your field engineers. It provides powerful features for field applications. Plus, the HSA’s superior performance gives you confidence in field test results while the optimized user interface enhances field productivity. A superior combination of low displayed average noise level (DANL) and single sideband (SSB) phase noise coupled with a narrow resolution bandwidth (RBW) means your signal measurements are more reliable and you will have more confidence in your test results.
Specifications.

Frequency
.
Range: 100 kHz to 7 GHz (usable to 9 kHz, Option BB1).

Frequency span.
Range: 0 Hz (zero span), 100 Hz to 7 GHz.
Resolution: 1 Hz.
Accuracy: ± (0.22% ×span + span/(sweep point −1)), nominal.

Sweep time.
Range: 2 ms to 1000 s (Span ≥ 100 Hz), 600 ns to 200 s (Span = 0 Hz(zero span)).
Mode: Continuous, Single.
Trigger Source: Free run, video, external, RF burst.

Resolution bandwidth (RBW).
Range (−3 dB bandwidth): 10 Hz to 3 MHz in 1-3-10 sequence.
Accuracy: ± 5%, RBW = 10 Hz to 1 MHz (Nominal), ± 10%, RBW = 3 MHz.

Measurement range.
100 kHz to 2 MHz: Displayed average noise level (DANL) to +10 dBm, Preamp off.
2 MHz to 7 GHz: Displayed average noise level (DANL) to +20 dBm, Preamp off.
Input attenuator range: 0 to 50 dB, in 1 dB steps.

Maximum safe input level.
Average continuous power: +33 dBm, 3 minutes maximum.
DC voltage: ± 50 VDC maximum.

Displayed average noise level (DANL) Preamp on, Normalized to 1 Hz.
  100 kHz to 1 MHz: −131 dBm, −150 dBm typical.
  1 to 10 MHz: −148 dBm, −163 dBm typical.
  10 to 500 MHz: −161 dBm, −164 dBm typical.
  500 to 2.5 GHz: −159 dBm, −162 dBm typical.
  2.5 to 4 GHz: −158 dBm, −161 dBm typical.
  4 to 6 GHz: −155 dBm, −158 dBm typical.
  6 to 7 GHz: −150 dBm, −154 dBm typical.

Options.
N9342C-AMA, AM/FM Modulation Analysis.
N9342C-BB1, Baseband Input.
N9342C-CA7, Handheld Cable and Antenna Tester, 5 MHz to 7 GHz.
N9342C-DMA, ASK/FSK Modulation Analysis.
N9342C-EMC, EMI filters and quasi-peak detector.
N9342C-GPS, Built-in GPS Receiver with Built-in GPS Antenna.
N9342C-PA7, Preamplifier, 7.0 GHz.
N9342C-PWM, USB Average Power Sensor Support (U2000 Series).
N9342C-PWP, USB Peak and Average Power Sensor Support (U2020/U2040 X-Series).
N9342C-SCN, Channel Scanner.
N9342C-SEC, Security Features.
N9342C-SIM, Spectrum Monitor with Spectrogram Record and Playback.
N9342C-TG7, Tracking Generator, 7 GHz.
N9342C-TMG, Time-Gated Spectrum Analysis.
N9342C-TPN, Task Planner for Test Automation.



 

Standard Calibration $625.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N9342C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) N9342C CALIBRATION and/or Keysight (Agilent) N9342C 7 GHz Handheld Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: