INSTEK LCR-6100 REPAIR and INSTEK LCR-6100 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the INSTEK LCR-6100. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK LCR-6100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK LCR-6100   Description / Specification:    
INSTEK LCR-6100 100kHz LCR Meter

The Instek LCR-6100 100kHz LCR Meter has a 3.5-inch color LCD to simultaneously display setting criteria and measurement results, it increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.
Specifications.

Test Frequency: 10Hz to 100kHz(±0.01%) (4 digits resolution).
Output impedance: 30Ω / 50Ω / 100Ω selectable.
Basic Accuracy: 0.05% (Slow / Med), 0.1% (Fast).
Test Speed: FAST:25ms / MED:100ms / SLOW:333ms.
Test Signal Levels.
  AC Voltage: 10.00mV to 2.00V (±10%), CV 10.00mV- to 2.00V (±6%).
  AC Current: 100.0μA to 20.00mA (±10%), CC 100.0μA to 20.00mA (±6%) (@2VMax).
  DCR: +2V, 0.066A (Max.), Output impedance fixed 30Ω.
DC Bias Internal: ±2.5V (0.5%+0.005V).
Display Range.
  R, X, |Z|: 0.00001Ω ~ 99.9999MΩ,
  G, B, |Y|: 0.01nS ~ 999.999S,
  L: 0.00001μH ~ 9999.99H,
  C: 0.00001pF ~ 9999.99mF,
  D: 0.00001 ~ 9.99999,
  Q: 0.00001 ~ 99999.9,
  θd: -179.999° ~ 179.999°,
  θr: -3.14159 ~ 3.14159,
  DCR: 0.00001Ω ~ 99.9999MΩ,
  Δ%: -99999% ~ 99999%.
Test Mode Combinations (16): Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK LCR-6100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your INSTEK LCR-6100 REPAIR and/or INSTEK LCR-6100 100kHz LCR Meter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: