FLUKE I400 CALIBRATION and FLUKE I400 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE I400 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE I400   Description / Specification:    
FLUKE I400 400 Amp AC Current Clamp Meter

The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, and 1 mA/Amp output guarantees easy reading. It has a compact shape and soft non-slippery overmold handle prevents from accidental touching live wiring. Features a CAT IV 600 V / CAT III 1000 V safety rating.
Specifications.

Max. conductor: 32 mm.
Nominal current range: 400 A.
Continuous current range: 1 A - 400 A.
Maximum non-destructive current: 1000 A.
Lowest measurable current: 1 A.
Basic accuracy: 2% + 0.06 A (45-400 Hz)(% reading + floorspec).
Usable frequency: 5 Hz - 20 kHz.
Output level(s): 1 mA/A.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE I400. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE I400 CALIBRATION and/or FLUKE I400 400 Amp AC Current Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: