FLUKE I400 CALIBRATION and FLUKE I400 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE I400 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE I400   Description / Specification:    
FLUKE I400 400 Amp AC Current Clamp Meter

The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, and 1 mA/Amp output guarantees easy reading. It has a compact shape and soft non-slippery overmold handle prevents from accidental touching live wiring. Features a CAT IV 600 V / CAT III 1000 V safety rating.
Specifications.

Max. conductor: 32 mm.
Nominal current range: 400 A.
Continuous current range: 1 A - 400 A.
Maximum non-destructive current: 1000 A.
Lowest measurable current: 1 A.
Basic accuracy: 2% + 0.06 A (45-400 Hz)(% reading + floorspec).
Usable frequency: 5 Hz - 20 kHz.
Output level(s): 1 mA/A.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE I400. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE I400 CALIBRATION and/or FLUKE I400 400 Amp AC Current Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: