PROTO 6062C CALIBRATION

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the PROTO 6062C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Torque Wrench? Shop for Comparable Products on our   new Torque Wrench page

 
   PROTO 6062C   Description / Specification:    
PROTO 6062C 40-200 in-lb 1/4" Drive Micrometer Adjustable Torque Wrench

The Proto 6062C Standard Ratcheting Head Micrometer Torque Wrench is calibrated to ±3% clockwise direction and ±6% counter clockwise direction at 20% to 100% of full scale. It is manufactured to meet standard industrial torque applications, general industry, heavy equipment, and maintenance. The 6062C is packaged in blow molded plastic box for protection and easy storage and meets ASME Standard.
Specifications / Features.

Drive Size: 1/4”.
Torque Range Minimum: 40 in-lbs.
Torque Range Maximum: 200 in-lbs.
Increments: 1 in-lbs.
Length: 11-7/8”.
Head Width: 1-1/32”.
Head Depth: 3/4”.



 



Related Mechanical Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Ball Micrometer
Ball micrometers have ball-shaped (spherical) anvils. They may have one flat and one ball anvil, in which case they are used for measuring tube wall thickness, distance of a hole to an edge, and other distances where one anvil must be placed against a rounded surface.

in-oz
Inch-ounce is a measurment of torque expressed as a force (ounce) multiplied by (i.e. “times”) a distance (inch). It is the amount of force applied in the direction of turning by one ounce on a one inch lever. To convert Inch-ounce to Inch-pound multiply by 0.0625. To convert Inch-ounce to Foot-pound (ft-lb) multiply by 0.0052.

Strain
A strain is a normalized measure of deformation representing the displacement between particles in the body relative to a reference length.


Please contact us for your PROTO 6062C CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: