3M 963E CALIBRATION and 3M 963E REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the 3M 963E Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   3M 963E   Description / Specification:    
3M 963E Benchtop Air Ionizer

The 3M 963E Benchtop Air Ionizer eliminates the build up of potentially damaging static charges. It is capable of reducing a static charge of 1000V to 100V in less than one second, at a one foot distance. In addition, the powerful fan allows the generated ions to be carried at high speed for long distances. At a distance of three feet, the discharge time only increases to approximately five seconds. The two-speed fan in the 3M Benchtop Air Ionizer 963E is extremely quiet at low speed.

Specifications.

Air Velocity:
  low speed - 100 fpm (0.5 m/s),
  high speed - 300 fpm (1.5 m/s).
Static Discharge Time (When tested according to ANSI/ESD S3.1-1991):
  1' (30 cm) < 1 second at high fan speed,
  3' (91 cm) < 5 second at high fan speed.



 

Standard Calibration $130.00 *
*This is a Web introductory price for one calibration of the 3M 963E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your 3M 963E CALIBRATION and/or 3M 963E Benchtop Air Ionizer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: