MEGGER MIT330 CALIBRATION and MEGGER MIT330 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MIT330 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MIT330   Description / Specification:    
MEGGER MIT330 250, 500, 1000 V Insulation Tester

The Megger MIT330 features the popular Megger digital/analogue display. Large 20mm high characters provide very clear readout, combined with an analogue arc for the feel of an analogue instrument, with a true analogue response.
Specifications

Insulation ranges
Nominal Test Voltage: 1000 V, 500 V, 250 V (d.c.).
Measuring Range: 10 kΩ - 999 MΩ on all ranges.
Short Circuit Current: 1.5 mA nominal.
Test Current on Load: 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364).
Accuracy (at 20 °C): ±3%, ±2 digits up to 10 MΩ, ±5% up to 100 MΩ, ±30% up to full scale

Continuity ranges
Measuring Range: 0,01 Ω - 99,9 Ω (0 -50 Ω on analogue scale).
Open Circuit Voltage: 5 V ±1 V.
Short Circuit Current: 205 mA +10 mA -5 mA.
Accuracy (at 20 °C): ±3% ±2 digits.
Measuring range: 0 - 2/20/200/2 kΩ.
Open circuit voltage: 1.5 V +/-0.5 V.
Zero Offset Adjust: 0 - 9 Ω.
Continuity Buzzer: Adjustable 1 Ω to 20 Ω.

Resistance range
Measuring Range: 10 Ω - 1 MΩ.
Open Circuit Voltage: 5 V.
Short Circuit Current: 1.5 mA.
Accuracy (at 20° C): ±5% ±2 digits up to 100 kΩ.

Default voltmeter all modes except off: >25 V a.c. or d.c. is applied display will operate as a voltmeter.
Test inhibit: If more than 50 volts is detected, testing will be inhibited.



 

Standard Calibration $270.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MIT330. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your MEGGER MIT330 CALIBRATION and/or MEGGER MIT330 250, 500, 1000 V Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: