SLAUGHTER 2935 CALIBRATION and SLAUGHTER 2935 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2935 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2935   Description / Specification:    
SLAUGHTER 2935 5KV AC, 6KV DC Withstanding Voltage Tester

The Slaughter 2935 Hipot tester was designed to provide safe, reliable, and cost-effective electrical safety testing. It complies with agency requirements from such agencies as UL, TÜV, CSA, VDE, and IEC.
Specifications.

Dielectric Withstand Test Mode.
Input Voltage: 115/230V selectable, ± 15% variation 47 - 63Hz.
Output Rating: AC 0 - 5000V, 2V/step, 12mA, DC 0 - 6000V, 2V/step, 5mA.
Output Regulation: ± (1% of output + 5V).
Voltage Setting: 0V - Max output rating, 10 volt step.
Voltage Setting Accuracy: ± (2% of Setting + 5V) (relative to displayed output).
Output Frequency: DC and 50/60Hz selectable.
Ripple: < 5% at 6KVDC/5mA.
Wave Form Sinewave Distortion : < 2% THD.
Dwell Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step “0” for continuous running.
Ramp Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step 0 ramp setting = 0.1 seconds fixed ramp.
Failure Settings AC Mode;
  High limit: 0.10 - 12.00mA, 0.01mA/step.
  Low limit: 0.00, 0.10 - 12.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Failure Settings DC Mode;
  High limit: 0.02 - 5.00mA, 0.01mA/step.
  Low limit: 0.00, 0.02 - 5.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Discharge Time: ≤ 300ms.
Ground Continuity Check;
  Current: DC 0.1A ± 0.01A, fixed.
  Maximum ground resistance: 1Ω ± 0.1Ω, fixed.



 

Standard Calibration $635.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2935. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your SLAUGHTER 2935 CALIBRATION and/or SLAUGHTER 2935 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: