Keysight (Agilent) 33521B CALIBRATION and Keysight (Agilent) 33521B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33521B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33521B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 33521B 30 MHz, 1 Ch Arbitrary Waveform Generator

The Keysight 33521B Waveform Generator with arbitrary capability offers exclusive Trueform Technology that gives it more capability, fidelity and flexibility than traditional DDS waveform generators. It has 17 arbitrary waveforms built-in, including standard waveforms such as sine, square, ramp, PRBS and Gaussian Noise. As well as specialty waveforms: Cardiac, Haversine, and Lorentz. Built-in modulations include AM, FM, PM FSK and PWM.
Specifications.

Maximum frequency: 30 MHz.
Number of channels: one.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, D-Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option MEM) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Counted Burst, Gated Burst.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Frequency range (Vout ≤ 10 Vpp): 1 μHz to 30 MHz, 1-μHz resolution.
Amplitude flatness relative to 1 kHz (Vout ≤ 10 Vpp);
  frequency out < 100 kHz: ± 0.10 dB,
  frequency out 100 kHz to 5 MHz: ± 0.15 dB,
  frequency out 5 MHz to 20 MHz: ± 0.30 dB,
  frequency out 20 MHz to 30 MHz: ± 0.40 dB.
Harmonic distortion typical (Vout ≤ 10 Vpp);
  frequency out < 20 kHz: < -70 dBc,
  frequency out 20 kHz to 100 kHz: < -65 dBc,
  frequency out 100 kHz to 1 MHz: < -50 dBc,
  frequency out 1 MHz to 20 MHz: < -40 dBc,
  frequency out 20 MHz to 30 MHz16: < -35 dBc.
THD typical (Vout ≤ 10 Vpp) frequency out = 20 Hz to 20 kHz: <0.04%.
Arbitrary waveform memory (volatile): 1 MSa/channel (16 MSa/channel with Option MEM), 512 sequence steps per channel.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 33521B CALIBRATION and/or Keysight (Agilent) 33521B 30 MHz, 1 Ch Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: