A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33521B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33521B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 33521B 30 MHz, 1 Ch Arbitrary Waveform Generator

The Keysight 33521B Waveform Generator with arbitrary capability offers exclusive Trueform Technology that gives it more capability, fidelity and flexibility than traditional DDS waveform generators. It has 17 arbitrary waveforms built-in, including standard waveforms such as sine, square, ramp, PRBS and Gaussian Noise. As well as specialty waveforms: Cardiac, Haversine, and Lorentz. Built-in modulations include AM, FM, PM FSK and PWM.
Specifications.

Maximum frequency: 30 MHz.
Number of channels: one.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, D-Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option MEM) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Counted Burst, Gated Burst.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Frequency range (Vout ≤ 10 Vpp): 1 μHz to 30 MHz, 1-μHz resolution.
Amplitude flatness relative to 1 kHz (Vout ≤ 10 Vpp);
  frequency out < 100 kHz: ± 0.10 dB,
  frequency out 100 kHz to 5 MHz: ± 0.15 dB,
  frequency out 5 MHz to 20 MHz: ± 0.30 dB,
  frequency out 20 MHz to 30 MHz: ± 0.40 dB.
Harmonic distortion typical (Vout ≤ 10 Vpp);
  frequency out < 20 kHz: < -70 dBc,
  frequency out 20 kHz to 100 kHz: < -65 dBc,
  frequency out 100 kHz to 1 MHz: < -50 dBc,
  frequency out 1 MHz to 20 MHz: < -40 dBc,
  frequency out 20 MHz to 30 MHz16: < -35 dBc.
THD typical (Vout ≤ 10 Vpp) frequency out = 20 Hz to 20 kHz: <0.04%.
Arbitrary waveform memory (volatile): 1 MSa/channel (16 MSa/channel with Option MEM), 512 sequence steps per channel.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33521B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 33521B CALIBRATION and/or Keysight (Agilent) 33521B 30 MHz, 1 Ch Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: