Keysight (Agilent) 33512B CALIBRATION and Keysight (Agilent) 33512B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33512B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33512B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 33512B 20 MHz, 2 Ch Arbitrary Waveform Generator

The Keysight 33512B Waveform Generator with arbitrary capability offers exclusive Trueform Technology that gives it more capability, fidelity and flexibility than traditional DDS waveform generators. It has 17 arbitrary waveforms built-in, including standard waveforms such as sine, square, ramp, PRBS and Gaussian Noise. As well as specialty waveforms: Cardiac, Haversine, and Lorentz. Built-in modulations include AM, FM, PM FSK and PWM.
Specifications.

Maximum frequency: 20 MHz.
Number of channels: two.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, D-Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option MEM) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Counted Burst, Gated Burst.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Frequency range (Vout ≤ 10 Vpp): 1 μHz to 30 MHz, 1-μHz resolution.
Amplitude flatness relative to 1 kHz (Vout ≤ 10 Vpp);
  frequency out < 100 kHz: ± 0.10 dB,
  frequency out 100 kHz to 5 MHz: ± 0.15 dB,
  frequency out 5 MHz to 20 MHz: ± 0.30 dB,
  frequency out 20 MHz to 30 MHz: ± 0.40 dB.
Harmonic distortion typical (Vout ≤ 10 Vpp);
  frequency out < 20 kHz: < -70 dBc,
  frequency out 20 kHz to 100 kHz: < -65 dBc,
  frequency out 100 kHz to 1 MHz: < -50 dBc,
  frequency out 1 MHz to 20 MHz: < -40 dBc,
  frequency out 20 MHz to 30 MHz: < -35 dBc.
THD typical (Vout ≤ 10 Vpp) frequency out = 20 Hz to 20 kHz: <0.04%.
Arbitrary waveform memory (volatile): 1 MSa/channel (16 MSa/channel with Option MEM), 512 sequence steps per channel.
Operating modes: Independent, Coupled parameter(s), Combined (Ch 1 + Ch 2), Equal (Ch 1 = Ch 2), or Differential (Ch 1 = −Ch 2).



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33512B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 33512B CALIBRATION and/or Keysight (Agilent) 33512B 20 MHz, 2 Ch Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: