Keysight (Agilent) DSO1052B CALIBRATION and Keysight (Agilent) DSO1052B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO1052B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO1052B   Description / Specification:    
Keysight (Agilent) DSO1052B 2 Ch 50 MHz Oscilloscope

The Agilent DSO1052B 50 MHz oscilloscope comes equipped with 23 automatic voltage, time and frequency measurements. Record up to 1000 occurrences of a trigger event and then play them back to easily spot glitches or other anomalies for further examination. Apply a real-time digital filter of your choice to the input source waveform to eliminate unwanted frequencies from your display. Digital filtering selections include Low-pass, high-pass, band-pass and band-reject filters.
Specifications.

Bandwidth (-3 dB) : DC to 50 MHz.
Real time sample rate: 1 GSa/sec half channel interleaved, 500 MSa/sec all channels.
Channels: 2.
Memory: 16 kpts half channel interleaved, 8 kpts all channels.
Vertical resolution: 8 bits.
Vertical sensitivity: 2 mV/div to 10 V/div.
DC gain accuracy: 2 mV/div to 5 mV/div: ± 4.0% full scale; 10 mV/div to 10 V/div: ± 3.0% full scale.
Vertical zoom: Vertical expand.
Maximum input voltage: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk.
Time base range: 5 nsec/div to 50 sec/div.
Selectable BW limit: 20 MHz.
Horizontal modes: Main (Y-T), XY, delayed zoom and roll.
Input coupling: DC, AC, Ground.
Input impedance: 1 MΩ ± 2% in parallel with 15 pF ± 3 pF.
Time scale accuracy: ± 50 ppm over 1 ms.
Display: 5.7 inch diagonal color QVGA TFT LCD display with 300 cd/m2 backlight intensity.



 

Standard Calibration $300.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO1052B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) DSO1052B CALIBRATION and/or Keysight (Agilent) DSO1052B 2 Ch 50 MHz Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: