Keysight (Agilent) DSO1072B CALIBRATION and Keysight (Agilent) DSO1072B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO1072B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO1072B   Description / Specification:    
Keysight (Agilent) DSO1072B 2 Ch 70 MHz Oscilloscope

The Agilent DSO1072B 70 MHz oscilloscope comes equipped with 23 automatic voltage, time and frequency measurements. Record up to 1000 occurrences of a trigger event and then play them back to easily spot glitches or other anomalies for further examination. Apply a real-time digital filter of your choice to the input source waveform to eliminate unwanted frequencies from your display. Digital filtering selections include Low-pass, high-pass, band-pass and band-reject filters.
Specifications.

Bandwidth (-3 dB) : DC to 70 MHz.
Real time sample rate: 1 GSa/sec half channel interleaved, 500 MSa/sec all channels.
Channels: 2.
Memory: 16 kpts half channel interleaved, 8 kpts all channels.
Vertical resolution: 8 bits.
Vertical sensitivity: 2 mV/div to 10 V/div.
DC gain accuracy: 2 mV/div to 5 mV/div: ± 4.0% full scale; 10 mV/div to 10 V/div: ± 3.0% full scale.
Vertical zoom: Vertical expand.
Maximum input voltage: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk.
Time base range: 5 nsec/div to 50 sec/div.
Selectable BW limit: 20 MHz.
Horizontal modes: Main (Y-T), XY, delayed zoom and roll.
Input coupling: DC, AC, Ground.
Input impedance: 1 MΩ ± 2% in parallel with 15 pF ± 3 pF.
Time scale accuracy: ± 50 ppm over 1 ms.
Display: 5.7 inch diagonal color QVGA TFT LCD display with 300 cd/m2 backlight intensity.



 

Standard Calibration $300.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO1072B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) DSO1072B CALIBRATION and/or Keysight (Agilent) DSO1072B 2 Ch 70 MHz Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: