Keysight (Agilent) DSO1102B CALIBRATION and Keysight (Agilent) DSO1102B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO1102B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO1102B   Description / Specification:    
Keysight (Agilent) DSO1102B 2 Ch 100 MHz Oscilloscope

The Agilent DSO1102B 100 MHz oscilloscope comes equipped with 23 automatic voltage, time and frequency measurements. Record up to 1000 occurrences of a trigger event and then play them back to easily spot glitches or other anomalies for further examination. Apply a real-time digital filter of your choice to the input source waveform to eliminate unwanted frequencies from your display. Digital filtering selections include Low-pass, high-pass, band-pass and band-reject filters.
Specifications.

Bandwidth (-3 dB) : DC to 100 MHz.
Real time sample rate: 1 GSa/sec half channel interleaved, 500 MSa/sec all channels.
Channels: 2.
Memory: 16 kpts half channel interleaved, 8 kpts all channels.
Vertical resolution: 8 bits.
Vertical sensitivity: 2 mV/div to 10 V/div.
DC gain accuracy: 2 mV/div to 5 mV/div: ± 4.0% full scale; 10 mV/div to 10 V/div: ± 3.0% full scale.
Vertical zoom: Vertical expand.
Maximum input voltage: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk.
Time base range: 2 nsec/div to 50 sec/div.
Selectable BW limit: 20 MHz.
Horizontal modes: Main (Y-T), XY, delayed zoom and roll.
Input coupling: DC, AC, Ground.
Input impedance: 1 MΩ ± 2% in parallel with 15 pF ± 3 pF.
Time scale accuracy: ± 50 ppm over 1 ms.
Display: 5.7 inch diagonal color QVGA TFT LCD display with 300 cd/m2 backlight intensity.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) DSO1102B CALIBRATION and/or Keysight (Agilent) DSO1102B 2 Ch 100 MHz Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: