A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1191A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) U1191A   Description / Specification:    
Keysight (Agilent) U1191A 400A Handheld Clamp Multimeter

The Keysight U1191A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: Average responding.

DC Voltage;
 Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
 Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
 Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
 Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
AC Voltage;
 Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
 Range: 400 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) U1191A CALIBRATION and/or Keysight (Agilent) U1191A 400A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?