Keysight (Agilent) U1193A CALIBRATION and Keysight (Agilent) U1193A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1193A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) U1193A   Description / Specification:    
Keysight (Agilent) U1193A 600A Handheld Clamp Multimeter

The Keysight U1193A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: True RMS.

DC Voltage;
  
Range: 60 V, 0.01 V (Resolution), 0.5% + 3 (Accuracy).
  Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
  Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
  Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
  Range: 60 kΩ, 0.01 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
  Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
AC Voltage;
  Range: 60 V, 0.01 V (Resolution), 1.2% + 5 (Accuracy).
  Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
  Range: 60 A, 0.01 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
  Range: 600 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
Capacitance;
  Range: 600 μF, 0.1 μF (Resolution), 2.0% + 4 (Accuracy).
  Range: 6 mF, 0.001 mF (Resolution), 2.0% + 4 (Accuracy).
Frequency;
  Range: 99.99 Hz, 0.01 Hz (Resolution), 0.5% + 3 (Accuracy).
  Range: 999.9 Hz, 0.1 Hz (Resolution), 0.5% + 3 (Accuracy).
  Range: 9.999 kHz, 0.001 kHz (Resolution), 0.5% + 3 (Accuracy).
  Range: 99.99 kHz, 0.01 kHz (Resolution), 0.5% + 3 (Accuracy).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) U1193A CALIBRATION and/or Keysight (Agilent) U1193A 600A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: