Keysight (Agilent) 4284A REPAIR and Keysight (Agilent) 4284A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 4284A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 4284A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 4284A   Description / Specification:    
Keysight (Agilent) 4284A Precision LCR Meter

The Agilent 4284A precision LCR meter is a cost-effective solution for component and material measurement. It can be used to improve component quality by providing an accurate, high-throughput test solution. The wide 20 Hz to 1 MHz test frequency range and superior test-signal performance allow the HP 4284A to test components to the most commonly-used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Features. 20 Hz to 1 MHz, with over 8,600 test frequencies. 0.05% basic accuracy, 6-digit resolution. Constant V or I test signal level. 20 Vrms level option (Option 001). 40 Adc with HP 42841A. List sweep measurement capability. Specifications. Parameters Measured: |Z| -Theta, |Y| -Theta, R-X, G-B; C-D, Q, ESR, G, Rp; L-D, Q, ESR, G, Rp; Deviation and % deviation. Measurement Circuit Modes: Series and parallel. Ranging: Auto and manual. Trigger: Internal, external, manual, and bus (HP-IB). Delay Time: 0 to 60.000s in 1 ms steps. Measurement Terminals: Four-terminal pair. Test Cable Length: Standard: 0 and 1 m; with Option 006: 0, 1, 2 and 4 m. Integration Time: Short, medium, and long. Averaging: 1 to 256, programmable. Test Signal: 20 Hz to 1 MHz ± 0.01%, 8610 selectable frequencies. DC Bias: Standard: 0 V, 1.5 V and 2 V. Options. Opt 001 Power Amplifier/DC Bias. Opt 002 Bias Current Interface. (Options 001 and 002 do not operate simultaneously.) Opt 004 Memory Card. Opt 006 2m/4m Cable Length Operation. Opt 109 Delete HP-IB Interface. Opt 201 General-Purpose Handler Interface. Opt 202 Handler Interface. Opt 301 Scanner Interface.



 

Standard Calibration $500.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 4284A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your Keysight (Agilent) 4284A REPAIR and/or Keysight (Agilent) 4284A Precision LCR Meter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: