Keysight (Agilent) B1517A REPAIR and Keysight (Agilent) B1517A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) B1517A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B1517A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   Keysight (Agilent) B1517A   Description / Specification:    
Keysight (Agilent) B1517A  High resolution source/monitor unit

The Agilent B1517A High resolution source/monitor plug-in module features a range up to 100 V/0.1 A with 4-quadrant operation. Minimum measurement resolution 1 fA/0.5 μV. Optional ASU (atto-sense and switch unit) for 100 aA resolution and IV/CV switching capability. It uses one slot in a B1500A Mainframe.
Specifications.

Voltage (high resolution ADC).
Range, Force resolution, Measure resolution, Force accuracy ±(% read value + offset voltage V), Measure accuracy (% read value + offset voltage V).
  ±0.5 V, 25 μV, 0.5 μV, ±(0.018% + 150 μV), ±(0.01% + 120 μV).
  ±2 V, 100 μV, 2 μV, ±(0.018% + 400 μV), ±(0.01% + 140 μV).
  ±5 V, 250 μV, 5 μV, ±(0.018% + 750 μV), ±(0.009% + 250 μV).
  ±20 V, 1 mV, 20 μV, ±(0.018% + 3 mV), ±(0.009% + 900 μV).
  ±40 V, 2 mV, 40 μV, ±(0.018% + 6 mV), ±(0.01% + 1 mV).
  ±100 V, 5 mV, 100 μV, ±(0.018% + 15 mV), ±(0.012% + 2.5 mV).

Current (high resolution ADC).
Range, Force resolution, Measure resolution, Force accuracy ±(% + A + A), Measure accuracy (% + A + A), Max voltage.
  ±10 pA, 5 fA, 1 fA, ±(0.46%+30 fA+10 aA x Vo), ±(0.46%+15 fA+10 aA x Vo), 100 V.
  ±100 pA, 5 fA, 2 fA, ±(0.3%+100 fA+100 aA x Vo), ±(0.3%+30 fA+100 aA x Vo), 100 V.

Power consumption.
Voltage source mode (Ic is the current compliance setting):
  20 x Ic (W) (0.5 to 20V),
  40 x Ic (W) (40V),
  100 x Ic (W) (100V).
Current source mode (Vc is the voltage compliance setting and Io is output current):
  20 x Io (W) (Vc ≤ 20),
  40 x Io (W) (20 < Vc ≤ 40),
  100 x Io (W) (40 < Vc ≤ 100).



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) B1517A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) B1517A REPAIR and/or Keysight (Agilent) B1517A High resolution source/monitor unit CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: