Custom-Cal has a high success rate in the repair of the Keysight (Agilent) B1517A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B1517A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   Keysight (Agilent) B1517A   Description / Specification:    
Keysight (Agilent) B1517A  High resolution source/monitor unit

The Agilent B1517A High resolution source/monitor plug-in module features a range up to 100 V/0.1 A with 4-quadrant operation. Minimum measurement resolution 1 fA/0.5 μV. Optional ASU (atto-sense and switch unit) for 100 aA resolution and IV/CV switching capability. It uses one slot in a B1500A Mainframe.
Specifications.

Voltage (high resolution ADC).
Range, Force resolution, Measure resolution, Force accuracy ±(% read value + offset voltage V), Measure accuracy (% read value + offset voltage V).
  ±0.5 V, 25 μV, 0.5 μV, ±(0.018% + 150 μV), ±(0.01% + 120 μV).
  ±2 V, 100 μV, 2 μV, ±(0.018% + 400 μV), ±(0.01% + 140 μV).
  ±5 V, 250 μV, 5 μV, ±(0.018% + 750 μV), ±(0.009% + 250 μV).
  ±20 V, 1 mV, 20 μV, ±(0.018% + 3 mV), ±(0.009% + 900 μV).
  ±40 V, 2 mV, 40 μV, ±(0.018% + 6 mV), ±(0.01% + 1 mV).
  ±100 V, 5 mV, 100 μV, ±(0.018% + 15 mV), ±(0.012% + 2.5 mV).

Current (high resolution ADC).
Range, Force resolution, Measure resolution, Force accuracy ±(% + A + A), Measure accuracy (% + A + A), Max voltage.
  ±10 pA, 5 fA, 1 fA, ±(0.46%+30 fA+10 aA x Vo), ±(0.46%+15 fA+10 aA x Vo), 100 V.
  ±100 pA, 5 fA, 2 fA, ±(0.3%+100 fA+100 aA x Vo), ±(0.3%+30 fA+100 aA x Vo), 100 V.

Power consumption.
Voltage source mode (Ic is the current compliance setting):
  20 x Ic (W) (0.5 to 20V),
  40 x Ic (W) (40V),
  100 x Ic (W) (100V).
Current source mode (Vc is the voltage compliance setting and Io is output current):
  20 x Io (W) (Vc ≤ 20),
  40 x Io (W) (20 < Vc ≤ 40),
  100 x Io (W) (40 < Vc ≤ 100).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) B1517A REPAIR and/or Keysight (Agilent) B1517A High resolution source/monitor unit CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: