THORLABS OSA201C CALIBRATION and THORLABS OSA201C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the THORLABS OSA201C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   THORLABS OSA201C   Description / Specification:    
THORLABS OSA201C 350 to 1100 nm USB Optical Spectrum Analyzer

The Thorlabs OSA201C Optical Spectrum Analyzer is a general-purpose instrument that measures optical power as a function of wavelength. It has a user friendly Graphical User Interface and can be controlled from a standard PC via High Speed USB 2.0 port. It is a Fourier Transform Optical Spectrum Analyzer (FT-OSA), which utilizes a scanning Michelson Interferometer in a push/pull configuration. This approach allows for the design of a full-featured OSA with the additional benefit of a high precision Wavelength Meter.
Specifications.

Wavelength Range: 350 - 1100 nm.
Spectral Resolution: 7.5 GHz.
Spectral Accuracy: ±2 ppm.
Spectral Precision: 1 ppm.
Wavelength Meter Resolution: 0.1 ppm, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Display Resolution: 9 Decimals, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Accuracy: ±1 ppm.
Wavelength Meter Precision: 0.2 ppm.
Input Power (Max), CW Source: 10 mW (10 dBm).
Input Damage Threshold: 20 mW (13 dBm).
Power Level Accuracy: ±1 dB.
Optical Rejection Ratio: 30 dB.
Level Sensitivity: -60 dBm/nm.



 

Standard Calibration $850.00 *
*This is a Web introductory price for one calibration of the THORLABS OSA201C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Broadband Source (BBS)
A Broadband Source is a spectrally large source that emits a signal which contains a continuous range of frequencies with a broad optical bandwidth (usually 100 nm or more). Sometimes called a white light source, there are two different meanings of this term. Visible white light and a source which does not necessarily emit in the visible spectral region.

Coherence
Coherence is the pattern and or relationships of waves due to phase properties.

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Power Flatness Over Modulation
When changing the wavelength and modulation frequency, and measuring the differences between actual and displayed power levels (in dB), the power flatness is ± half the span between the maximum and the minimum value of all differences.

Singlemode fiber
Singlemode Fiber has a small core, only about 9 microns, and is used for telephony and CATV with laser sources at 1300 and 1550 nm. It can go very long distances at very high speeds. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.


Please contact us for your THORLABS OSA201C CALIBRATION and/or THORLABS OSA201C 350 to 1100 nm USB Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: