A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DSX-602 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DSX-602   Description / Specification:    
FLUKE DSX-602 500 MHz CableAnalyzer

The Fluke DSX-602 CableAnalyzer is the essential certification tool for copper, twisted pair structured cabling from Cat 3 / Class C through Cat 6A / Class EA. It features speed and reliability that makes you more efficient and productive - you can see the results on the bottom line. Its gesture-based user interface allows your techs to spend less time interpreting screens and more time testing. The 500 MHz frequency range certifies Cat 6A/Class EA cabling for 10 Gigabit Ethernet in just 10 seconds. Advanced diagnostics pinpoint the location of a failure. It performs Class E/Cat 6 certification tests in just 9 seconds and Class EA/Cat 6A in 10 seconds
Specifications.

Cable Types.
Shielded and unshielded pair LAN cabling: Category 3, 5, 5e, 6, 6A per TIA 568-C.2 or TIA-1005.

Test Standards.
TIA: Category 3, 5, 5e, 6, 6A per TIA 568-C.2 or TIA-1005.
ISO/IEC: Class C and D, E, EA certification per ISO/IEC 11801:2002 and amendments.
IEEE: 802.3 10BASE-T, 100BASE-TX, 1000BASE-T, 10GBASE-T.
Maximum frequency: 500 MHz.

General.
Speed of Autotest: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds; Full 2-way Autotest of Category 6A/Class EA: 10 seconds.
Input protection: Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.
Display: 5.7 in LCD display with a projected capacitance touchscreen.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE DSX-602 CALIBRATION and/or FLUKE DSX-602 500 MHz CableAnalyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: