FLUKE DSX-602 CALIBRATION and FLUKE DSX-602 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DSX-602 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DSX-602   Description / Specification:    
FLUKE DSX-602 500 MHz CableAnalyzer

The Fluke DSX-602 CableAnalyzer is the essential certification tool for copper, twisted pair structured cabling from Cat 3 / Class C through Cat 6A / Class EA. It features speed and reliability that makes you more efficient and productive - you can see the results on the bottom line. Its gesture-based user interface allows your techs to spend less time interpreting screens and more time testing. The 500 MHz frequency range certifies Cat 6A/Class EA cabling for 10 Gigabit Ethernet in just 10 seconds. Advanced diagnostics pinpoint the location of a failure. It performs Class E/Cat 6 certification tests in just 9 seconds and Class EA/Cat 6A in 10 seconds
Specifications.

Cable Types.
Shielded and unshielded pair LAN cabling: Category 3, 5, 5e, 6, 6A per TIA 568-C.2 or TIA-1005.

Test Standards.
TIA: Category 3, 5, 5e, 6, 6A per TIA 568-C.2 or TIA-1005.
ISO/IEC: Class C and D, E, EA certification per ISO/IEC 11801:2002 and amendments.
IEEE: 802.3 10BASE-T, 100BASE-TX, 1000BASE-T, 10GBASE-T.
Maximum frequency: 500 MHz.

General.
Speed of Autotest: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds; Full 2-way Autotest of Category 6A/Class EA: 10 seconds.
Input protection: Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.
Display: 5.7 in LCD display with a projected capacitance touchscreen.



 

Standard Calibration $625.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DSX-602. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE DSX-602 CALIBRATION and/or FLUKE DSX-602 500 MHz CableAnalyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: