A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U1192A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEYSIGHT U1192A   Description / Specification:    
KEYSIGHT U1192A 400A Handheld Clamp Multimeter

The Keysight U1192A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: Average responding.

DC Voltage;
Range: 60 V, 0.01 V (Resolution), 0.5% + 3 (Accuracy).
Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
Range: 60 kΩ, 0.01 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
AC Voltage;
Range: 60 V, 0.01 V (Resolution), 1.2% + 5 (Accuracy).
Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
Range: 60 A, 0.01 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
Range: 400 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
Capacitance;
Range: 600 μF, 0.1 μF (Resolution), 2.0% + 4 (Accuracy).
Range: 6 mF, 0.001 mF (Resolution), 2.0% + 4 (Accuracy).
Frequency;
 Range: 99.99 Hz, 0.01 Hz (Resolution), 0.5% + 3 (Accuracy).
 Range: 999.9 Hz, 0.1 Hz (Resolution), 0.5% + 3 (Accuracy).
 Range: 9.999 kHz, 0.001 kHz (Resolution), 0.5% + 3 (Accuracy).
 Range: 99.99 kHz, 0.01 kHz (Resolution), 0.5% + 3 (Accuracy).



 

Standard Calibration $150.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U1192A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your KEYSIGHT U1192A CALIBRATION and/or KEYSIGHT U1192A 400A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: