A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U1241C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   KEYSIGHT U1241C   Description / Specification:    
KEYSIGHT U1241C True RMS 10k Count Handheld Digital Multimeter

The Keysight U1241C True RMS 10k Count Handheld Digital Multimeter is certified to IP 67 and with the durability to withstand drops up to 10 feet (3 meters) to suit harsh working environments, the U1241C can work longer for you with up to 400 hours of battery life. Better yet, you can optimize productivity with the unique remote data logging functionality via USB or Bluetooth. Includes continuity with beeper and diode test.
Specifications.

DC Voltage Range: 100 mV to 1000 V.
DC Voltage Accuracy: 0.09% + 2 cnts.
AC Voltage Range: 100 mV to 1000 V.
AC Voltage Accuracy: 1.0% + 3 cnts (40 Hz to 1 kHz).
DC Current Range: 1000 μA to 10 A.
DC Current Accuracy: 0.1% + 2 cnts (1000 μA to 10 mA).
AC Current Range: 1000 μA to 10 A.
AC Current Accuracy: 1% + 3 cnts (1000 μA to 1000 mA).
Resistance Range: 1000 Ω to 100 MΩ.
Resistance Accuracy: 0.2% + 2 cnts (1000 Ω to 1000 kΩ).
Frequency Range: 100 Hz to 10 MHz.
Frequency Accuracy: 0.02% + 1 cnts (< 1 MHz).
Capacitance Range: 1000 nF to 10 mF.
Capacitance Accuracy: 1% + 5 cnts (1000 nF to 100 μF).
Temperature Thermal type K Range: -200°C to 1372°C.
Temperature Thermal type K Accuracy: 1% + 1°C.

Display: 4 ½-digit liquid crystal display (LCD) with maximum reading of 11,000-count.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your KEYSIGHT U1241C CALIBRATION and/or KEYSIGHT U1241C True RMS 10k Count Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: