KEYSIGHT N9310A CALIBRATION and KEYSIGHT N9310A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N9310A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   KEYSIGHT N9310A   Description / Specification:    
KEYSIGHT N9310A 3  GHz RF Signal Generator

The Keysight N9310A is a general purpose RF signal generator covering a frequency range from 9 kHz to 3 GHz. It's suited for R&D, manufacturing, education, and service maintenance.
Specifications.

Frequency Range: 9 kHz to 3.0 GHz.
Frequency Resolution: 0.1 Hz.
Frequency Switching speed: < 10 ms, Within 0.1 ppm of final frequency.
Frequency reference Aging rate: ±1 ×10^-6 / year.
Timebase reference output Frequency: 10 MHz.
Timebase reference Amplitude: > 0.35 Vrms level into 50 ohm.
External reference input Range: 2 MHz, 5 MHz, 10 MHz.
External reference input Amplitude: 0.5 to 2 Vrms.
Output Power: -127 to +13 dBm, +20 dBm settable.
Output Resolution: 0.1 dB.
Output Accuracy: < ±1dB Fc >= 100 kHz, -120 <= Level <= +13 dBm, 20 to 30 °C.
Reversal power protection DC voltage: 30 V.
Reversal power protection RF power: +36 dBm, 1 minute; the warning for reversed power protection is nominally at +25 dBm.
SSB phase noise: < -95 dBc/Hz, Typical, Fc = 1 GHz at 20 kHz offset.
Harmonics: < -30 dBc, Level <= 0 dBm, Fc >= 1 MHz.
Amplitude modulation (Fc >= 100 kHz) Range: 0 to 100%, Envelope peak < maximum specified power.
Frequency modulation (Fc >=100 kHz) Frequency deviation: 20 Hz to 100 kHz.
Phase modulation (Fc >=100 kHz) Phase deviation: 0 to 10 rad (Rate <= 10 kHz), 0 to 5 rad (10 kHz < rate <= 20 kHz).
Pulse modulation On/Off ratio: >= 40 dB.
Standard USB connectivity for test automation and flash memory support.

Options.
001, Add Analog IQ Input Capability.
PFR, Precision frequency reference.



 

Standard Calibration $415.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT N9310A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your KEYSIGHT N9310A CALIBRATION and/or KEYSIGHT N9310A 3 GHz RF Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: