ANRITSU MS2028B CALIBRATION and ANRITSU MS2028B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2028B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS2028B   Description / Specification:    
ANRITSU MS2028B 20 GHz VNA Master Handheld Vector Network Analyzer

The Anritsu MS2028B VNA Master is a handheld solution to address cable and antenna measurement needs in the field. The MS2028B VNA Master covers applications up to 20 GHz, which contains a wide variety of RF and microwave systems, both coax and waveguide. Equally impressive, this measurement tool offers the industry’s first 12-term error correction algorithm in a handheld VNA. With typical measurement speed of 750 μsec/point, the VNA Master is also ideally suited for transmission measurements anytime, anywhere.
Specifications.

Frequency Range: 5 kHz to 20 GHz.
Frequency Accuracy: 1.5 ppm.
Frequency Resolution: 1 kHz.
Typical Test Port Power:
  5 kHz to ≤ 3 GHz; +3 dBm (High Port) -25 dBm (Low Port),
  3 GHz to ≤ 6 GHz; +3 dBm (High Port) -25 dBm (Low Port),
  6 GHz to ≤ 20 GHz; +3 dBm (High Port) -15 dBm (Low Port).
Transmission Dynamic Range:
  5 kHz to ≤ 3 GHz 80dB,
  3 GHz to ≤ 6 GHz 75 dB,
  6 GHz to ≤ 20 GHz 65 dB.
Typical Sweep Speed: 525 μs/point (5 kHz to 6 GHz), 750 μs/point (5 kHz to 20 GHz).
Dynamic Range: 65 dB.
IF Bandwidth: 10, 30, 100, 300, 1k, 3k, 10k, 30k, 100k (Hz).
Data Points: 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.
Maximum Input (Damage Level) into Vector Network Analyzer: +23 dBm, ±50 VDC.

Options.
MS2028B-0002 Time Domain (includes DTF capability).
MS2028B-0005 Power Monitor (requires external detector).
MS2028B-0007 Secure Data Operation.
MS2028B-0010 Built-in Bias-Tee.
MS2028B-0011 K(f) Test Port Connectors.
MS2028B-0015 Vector Voltmeter.
MS2028B-0019 High Accuracy Power Meter (requires external USB sensor).
MS2028B-0031 GPS Receiver (requires GPS antenna, 2000-1528-R).
MS2028B-0077 Balanced/Differential S-Parameters, 1-port.



 

Standard Calibration $700.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS2028B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your ANRITSU MS2028B CALIBRATION and/or ANRITSU MS2028B 20 GHz VNA Master Handheld Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*