A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2028B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS2028B   Description / Specification:    
ANRITSU MS2028B 20 GHz VNA Master Handheld Vector Network Analyzer

The Anritsu MS2028B VNA Master is a handheld solution to address cable and antenna measurement needs in the field. The MS2028B VNA Master covers applications up to 20 GHz, which contains a wide variety of RF and microwave systems, both coax and waveguide. Equally impressive, this measurement tool offers the industry’s first 12-term error correction algorithm in a handheld VNA. With typical measurement speed of 750 μsec/point, the VNA Master is also ideally suited for transmission measurements anytime, anywhere.
Specifications.

Frequency Range: 5 kHz to 20 GHz.
Frequency Accuracy: 1.5 ppm.
Frequency Resolution: 1 kHz.
Typical Test Port Power:
  5 kHz to ≤ 3 GHz; +3 dBm (High Port) -25 dBm (Low Port),
  3 GHz to ≤ 6 GHz; +3 dBm (High Port) -25 dBm (Low Port),
  6 GHz to ≤ 20 GHz; +3 dBm (High Port) -15 dBm (Low Port).
Transmission Dynamic Range:
  5 kHz to ≤ 3 GHz 80dB,
  3 GHz to ≤ 6 GHz 75 dB,
  6 GHz to ≤ 20 GHz 65 dB.
Typical Sweep Speed: 525 μs/point (5 kHz to 6 GHz), 750 μs/point (5 kHz to 20 GHz).
Dynamic Range: 65 dB.
IF Bandwidth: 10, 30, 100, 300, 1k, 3k, 10k, 30k, 100k (Hz).
Data Points: 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.
Maximum Input (Damage Level) into Vector Network Analyzer: +23 dBm, ±50 VDC.

Options.
MS2028B-0002 Time Domain (includes DTF capability).
MS2028B-0005 Power Monitor (requires external detector).
MS2028B-0007 Secure Data Operation.
MS2028B-0010 Built-in Bias-Tee.
MS2028B-0011 K(f) Test Port Connectors.
MS2028B-0015 Vector Voltmeter.
MS2028B-0019 High Accuracy Power Meter (requires external USB sensor).
MS2028B-0031 GPS Receiver (requires GPS antenna, 2000-1528-R).
MS2028B-0077 Balanced/Differential S-Parameters, 1-port.



 



Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ANRITSU MS2028B CALIBRATION and/or ANRITSU MS2028B 20 GHz VNA Master Handheld Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: