ANRITSU MS2025B CALIBRATION and ANRITSU MS2025B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2025B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS2025B   Description / Specification:    
ANRITSU MS2025B 6 GHz VNA Master Handheld Vector Network Analyzer

The Anritsu MS2025B VNA Master is a compact handheld solution to address cable, antenna, component, and signal analysis needs in the field. The VNA Master model offers benchtop accuracy and high performance S-parameter measurements in portable form. With frequency coverage from 500 kHz up to 6 GHz in a truly handheld, battery-operated, rugged, multi-function instrument, the VNA Master also provides a field-friendly touchscreen user interface.
Specifications.

Frequency Range: 500 kHz to 6 GHz.
Frequency Accuracy: 2.5 ppm.
Frequency Resolution: 1 Hz.
Test Port Power High Port Power:
  +3 dBm 500 kHz to < 3 GHz,
  0 dBm 3 GHz to 6 GHz.
Test Port Power Low Port Power: -25 dBm.
Maximum Input (Damage Level ) VNA Port 1 or 2: +23 dBm, ± 50 VDC.
Transmission Dynamic Range: 2 MHz to ≤ 4 GHz, 100 dB; 4 GHz to ≤ 6 GHz, 90 dB
Sweep Speed (Typical): 500 kHz to 6 GHz, 850 μs/point.
Noise Floor:
  500 kHz to 3 GHz -100 dBm,
  3 GHz to 4 GHz -103 dBm,
  4 GHz to 6 GHz -93 dBm.
Interference Immunity:
  On-Channel +17 dBm at > 1.0 MHz from carrier frequency,
  On-Frequency 0 dBm within ± 10 kHz of the carrier frequency.

Measurements.
Measurement Parameters: S11, S21.
Number of Traces Four: TR1, TR2, TR3, TR4.
Domains: Frequency Domain, Distance Domain.
Frequency: Start Frequency, Stop Frequency, Center Frequency, Span.
Distance: Start Distance, Stop Distance.
Frequency Sweep Type Linear: Single Sweep, Continuous.
Data Points: 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.


Options.
-010 Built-in Bias-Tee, +12 V to +32 V variable.
-015 Vector Voltmeter.
-019 High Accuracy Power Meter (requires external USB sensor, sold separately).
-031 GPS Receiver.



 



Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ANRITSU MS2025B CALIBRATION and/or ANRITSU MS2025B 6 GHz VNA Master Handheld Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: