KEYSIGHT N5247B CALIBRATION and KEYSIGHT N5247B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N5247B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   KEYSIGHT N5247B   Description / Specification:    
KEYSIGHT N5247B 67 GHz PNA-X Microwave Network Analyzer

The Keysight N5247B 10 MHz to 67 GHz PNA-X microwave network analyzer offers a versatile and fully integrated microwave test platform. Specializing in characterizing active devices like amplifiers, mixers, and frequency converters, the PNA-X hardware includes dual internal signal sources, a signal combiner, S-parameter and noise receivers, pulse modulators and generators, and a set of switches and RF access points. The hardware integrations offer a wide range of both linear and nonlinear measurements, all accessible through a single set of connections to your device under test (DUT).
Specifications.

Maximum System Dynamic Range, Opt 201/401: 131 dB (3.2 GHz to 26.5 GHz, Port 1, 3), 132 dB (1 GHz to 2 GHz, Port 2, 4).
Maximum System Dynamic Range, Opt 219/419: 130 dB (3.2 GHz to 10 GHz, Port 1, 3), 132 dB (1 GHz to 2 GHz, Port 2, 4).
Maximum Receiver Dynamic Range: 134 dB (1 GHz to 10 GHz).
Test Ports: 1.85 mm (male), 50 ohm (nominal), (nominal), 0.002 in. (characteristic).

Test Port Output.
Frequency Range: 10 MHz to 67 GHz, 900 Hz to 67 GHz (Option 425).
Frequency Resolution: 1 Hz.
Frequency Accuracy: ±0.7 ppm.
Initial Frequency Accuracy: ±0.2 ppm.
Frequency Stability Typical: ±0.05 ppm, -10° to 70° C.
Maximum Leveled Power, Opt 201/401: 13 dBm (3.2 GHz to 10 GHz, Port 1, 3), 13 dBm (50 MHz to 10 GHz, Port 2, 4).

Test Port Input.
Maximum Test Port Noise Floor: -118 dBm (16 GHz to 26.5 GHz).

Hardware options.
N5247B-201  2-port, configurable test set.
N5247B-219  2-port, configurable test set, source attenuators, receiver attenuators, bias tees.
N5247B-224  2-port, configurable test set, source attenuators, receiver attenuators, bias tees, second source, combiner, mechanical switches.
N5247B-401  4-port, configurable test set, second source.
N5247B-419  4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees.
N5247B-423  4-port, configurable test set, second source, source attenuators, receiver attenuators, bias tees, combiner, mechanical switches.
N5247B-425  4-port, configurable test set, second source, attenuators, combiner, mechanical switches, bias tees, low frequency extension.



 



Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your KEYSIGHT N5247B CALIBRATION and/or KEYSIGHT N5247B 67 GHz PNA-X Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: