KEYSIGHT N5224B CALIBRATION and KEYSIGHT N5224B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N5224B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   KEYSIGHT N5224B   Description / Specification:    
KEYSIGHT N5224B 43.5 GHz PNA Microwave Network Analyzer

The Keysight N5224B 10 MHz to 43.5 GHz PNA Microwave Network Analyzer has 2-ports with one source and 4-ports with two sources, source and receiver attenuators, bias-tees, pulse generators and modulators, noise figure, and best RF performance. It combines hardware and test software applications to measure a broad range of devices quickly and accurately.
Specifications.

Maximum System Dynamic Range, Opt 200/400: 135 dB (3.2 GHz to 10 GHz, Port 1, 3), 134 dB (1 GHz to 2 GHz, Port 2, 4).
Maximum System Dynamic Range, Opt 201/401: 135 dB (3.2 GHz to 10 GHz, Port 1, 3), 134 dB (1 GHz to 10 GHz, Port 2, 4).
Maximum Receiver Dynamic Range, Opt 200/400: 132 dB (10 GHz to 26.5 GHz).
Test Ports: 2.4 mm (male), 50 ohm, (nominal), 0.002 in. (characteristic).

Test Port Output.
Frequency Range: 10 MHz to 43.5 GHz, 900 Hz to 43.5 GHz (LFE Options).
Frequency Resolution: 1 Hz.
Frequency Accuracy: ±0.7 ppm.
Initial Frequency Accuracy: ±0.2 ppm.
Frequency Stability Typical: ±0.05 ppm, -10° to 70° C.
Maximum Leveled Power: 13 dBm (50 MHz to 35 GHz, Opt 200/400), 13 dBm (50 MHz to 26.5 GHz, Opt 201/401).

Test Port Input.
Maximum Test Port Noise Floor: -114 dBm (1 GHz to 26.5 GHz).

Hardware options.
N5224B-200  2-port, base hardware configuration.
N5224B-201  2-port with configurable test set, reference mixer switch.
N5224B-205  2-port with configurable test set, ref mixer switch, bias tees, low frequency extension.
N5224B-210  2-port with metrology configuration
N5224B-217  2-port with configurable test set, reference mixer switch, source and receiver attenuators.
N5224B-219  2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5224B-220  2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.
N5224B-400  4-port with second source.
N5224B-401  4-port with second source, configurable test set, reference mixer switch.
N5224B-405  4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension.
N5224B-410  4-port with second source, metrology configuration.
N5224B-417  4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators.
N5224B-419  4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5224B-420  4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.



 

Standard Calibration $865.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT N5224B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your KEYSIGHT N5224B CALIBRATION and/or KEYSIGHT N5224B 43.5 GHz PNA Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: