Keysight (Agilent) 53152A CALIBRATION and Keysight (Agilent) 53152A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53152A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53152A   Description / Specification:    
Keysight (Agilent) 53152A CW Microwave Counter with Power Measurement

The Agilent 53152A CW Microwave Counter with Power Measurement offers an uncluttered, feature laden front panel. These designs present no-compromise performance and quality in a surprisingly small, light, battery operated product. If AC power is unavailable, the internal, replaceable camcorder batteries provide at least 2.5 hours of continuous operation. The unit can also be powered from an external 11-18 Vdc source. Input Characteristics. Channel 1. Frequency Range (1 M-Ohm): 10 Hz to125 MHz. Resolution: Selectable 1 Hz to 1 MHz. Connector: BNC female. Low Pass Filter: 50 kHz, selectable. Channel 2. Frequency Range (50 Ohm): 0.05 to 46GHz. Resolution: Selectable 1 Hz to 1 MHz. Acquisition Time: 100 ms to 140 ms. Gate Time: 1/Resolution. FM Tolerance: 20 MHz p-p max. @ 10 MHz rate to 26.5 GHz; 12 MHz p-p max. @ 10 MHz rate to 46 GHz. AM Tolerance: Any depth/rate within dynamic range of input. Amplitude Discrimination (above 250 MHz): 20 dB typ. for greater than 75 MHz separation; 10 dB typ. for less than 75 MHz separation. Connector: 2.92 mm Planar Crown. Power Measurement. Range: Counter sensitivity to +7 dBm. Units: dBm or milliwatts/microwatts. Resolution: 0.01 dB. Display: Backlit LCD. Sample Rate: User-selectable Fast, Medium, Slow or Hold. Options. Opt 001: Oven Timebase. Opt 002: Battery/DC Input.



 

Standard Calibration $470.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53152A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 53152A CALIBRATION and/or Keysight (Agilent) 53152A CW Microwave Counter with Power Measurement REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: