A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS ML720 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS ML720   Description / Specification:    
EXTECH INSTRUMENTS ML720 True RMS MultiLog Multimeter

The Extech ML720 is a True RMS multilog multimeter that datalogs up to 43,000 data points at capture rates as fast as 20 times/second. MultiLog Meters measure AC/DC Voltage/Current, Resistance, Frequency, Capacitance, Temperature, Diode, and Continuity. The MultiLog™ Series meters offer a built-in datalogger and an optical RS-232 interface. The meters store measured data, 43,000 data points in internal memory.
Specifications.

DC/AC Voltage.
DC Range: 50mV, 500mV, 5V, 50V, 500V, 1000V @ ±(0.08%+2d) Basic Accuracy.
AC Range: 50mV, 500mV, 5V, 50V, 500V, 1000V @ ±(0.5%+3d) Basic Accuracy.
Resolution: 0.01 mV.

DC/AC Current.
DC Range: 500µA, 5000µA, 50mA, 500mA, 5A, 10A @ ±(0.2%+4d) Basic Accuracy.
AC Range: 500µA, 5000µA, 50mA, 500mA, 5A, 10A @ ±(0.6%+3d) Basic Accuracy.
Resolution: 0.1µA.

Resistance (Ω).
Range: 50, 500, 5k, 50k, 500k, 5M, 50M.
Resolution: 0.01 Ω.
Basic Accuracy: ±(0.1%+2d).

Capacitance.
Range: 50nF ,500nF, 5µF, 50µF, 500µF, 9999µF.
Resolution: 0 .01nF.
Basic Accuracy: ±(0.8%+3d).

Frequency.
Range: 10Hz to 125kHz.
Resolution: 0.001Hz.
Basic Accuracy: ±(0.01%+2d).
Temperature: -58F to 1832°F (-50 to 1000°C ), 1° @ ±(0.3%+3d).



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS ML720. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your EXTECH INSTRUMENTS ML720 CALIBRATION and/or EXTECH INSTRUMENTS ML720 True RMS MultiLog Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: