EXTECH INSTRUMENTS EX570 CALIBRATION and EXTECH INSTRUMENTS EX570 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX570 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX570   Description / Specification:    
EXTECH INSTRUMENTS EX570 True RMS Autoranging Multimeter with IR Thermometer

The Extech EX570 Industrial Multimeter with built-in infrared thermometer delivers every multimeter function you need, along with high accuracy and True RMS precision. It is designed to withstand harsh environments and usage with a rugged, double-molded housing. The large, illuminated LCD displays a five-digit readout (to 40,000 counts) and a useful 40-segment bar graph for analog comparisons and quick “needle-swing” tests. The EX570 offers a wide array of must-have multimeter measurements including capacitance, frequency, diode, continuity functions, plus convenient, one-button access to frequently used functions: Min/Max, Average, Hold, Relative, and Peak Hold, as well as selectable auto-ranging or manual-ranging.
Specifications.

Display Counts: 40,000 count.
Basic Accuracy: 0.06%.
DC/AC Voltage: 0.01mV to 1000VDC ; 0.1mV to 1000VAC.
DC/AC Current: 0.01μA to 20A.
Resistance: 0.01Ωto 40MΩ.
Capacitance: 0.001nF to 10,000μF.
Frequency: 0.0001Hz to 40MHz.
IR Temperature (301 ratio): -22 to 1022°F (-30 to 550°C).
Temperature (Type K): -50 to 1382°F (-45 to 750°C).
Duty Cycle: 0.01 to 99.99%.
Diode/Continuity: Yes.
Maximum Voltage AC: 1000 V.
Resolution AC Volts: 0.01 mV.
Maximum Voltage DC: 1000 V.
Resolution DC Volts: 0.01 mV.
Maximum Current AC: 20 A.
Minimum Current AC: 0.01 uA (0.00001 mA).
Resolution AC Current: 0.01 uA (0.00001 mA).
Maximum Current DC: 20 A.
Minimum Current DC: 0.01 uA (0.00001 mA).
Resolution DC Current: 0.01 uA (0.00001 mA).
Basic Accuracy V DC: .06%.



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX570. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your EXTECH INSTRUMENTS EX570 CALIBRATION and/or EXTECH INSTRUMENTS EX570 True RMS Autoranging Multimeter with IR Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: